Pos.
Part Name
Article #
Tube: ID x OD
Flow Range
Connector
Calibration Set
Note
1a
LFSC-05D-001
100-30407
ID = 1/8”= 3.2 mm
OD = 1/4”= 6.4 mm
1 lpm
Circular
Hirose
Water @ 20°C and
37°C
Silicone and C-Flex
®
Default activated calibration
set is Silicone at 37°C
water temperature.
Other parameter sets can
be chosen
with Levitronix
®
Service Software
.
1b
LFSC-08D-001
100-30396
ID = 1/4”= 6.4 mm
OD = 3/8”= 9.6 mm
4 lpm
1c
LFSC-12D-007
100-30390
ID = 3/8”=9.5 mm
OD = 9/16”=14.7 mm
20 lpm
1d
LFSC-22D-005
100-30391
ID = 3/4”=19.05 mm
OD = 1”=25.4 mm
80 lpm
1e
LFSC-30D-001
100-30414
ID = 1”=25.4 mm
OD = 13/8”=34.9 mm
160 lpm
Table 1: Standard flow sensor configurations
1: C-Flex
®
is a registered trademark of Saint Gobain Performance Plastics, 2015. All rights reserved.
Pos.
Part Name
Article #
Description
Interfaces
2
(A+6)
LFC-1C-PC
100-30374
Single Channel Converter
Analog Output (4
– 20 mA), 2x Digital Output, 1x Digital Input,
RS485 (MODBUS) protocol
Note: EMI ferrite (7) for flow sensor cable and signal connector (A) included in
converter package.
3
(A+B)
LFC-6CIO-PC
100-30446
6-Channel Converter
with I/O Interfaces
(Digital I/O connector A and analog
output connector B included)
RS485 (MODBUS) protocol
6 analog outputs (4
– 20 mA), 6 digital inputs, 6 digital outputs
Order Bus Conn. (6a) and Termination Box (6b) as separate article
Note 1: EMI ferrite (7) for supply/bus connection to be ordered as separate article.
When stacking multiple converters the EMI ferrite is needed on every sensor cable.
Note 2: Firmware version 08 or higher is necessary for the LFSC-D sensors.
4
(A-H)
LFC-1C-PC-SK
100-91072
Converter Starter Kit
Flow converter LFC-1C-PC (A) with Ferrite (B), AC/DC desktop supply
(C) with international AC mains inserts, sensor cable LFI-C.1-30 (D),
converter connection cable LFI-D.1 (E), RS485/USB cable YN-485I-TR
(F), USB stick with Levitronix Service Softw. and product Literature (G).
Table 2: LEVIFLOW
®
converters for clamp-on sensor
Pos.
Part Name
Article #
Features
Special Feature / Description
5a
LFI-C.1-10
LFI-C.1-30
LFI-C.1-60
190-10307
190-10308
190-10309
Cable length: 1 m, PVC
Cable length: 3 m, PVC
Cable length: 6 m, PVC
Interconnect cable for connection between sensor and converter.
5b
LFE-C.2-10
LFE-C.2-30
LFE-C.2-60
190-10310
190-10311
190-10312
Cable length: 1 m, PVC
Cable length: 3 m, PVC
Cable length: 6 m, PVC
Extension cable with wall-mountable connector for cabinet mounting.
Delivered with protective dust cap on wall-mountable connector side.
6a
Connector Box
for LFC-6CIO-PC
100-30447
COMBICON connector
For wiring RS485 and supply of stacks of LFC-6CIO-PC converter.
6b
Termination Box
for LFC-6C
100-30317
--
For termination of RS485 bus of LFC-6CIO-PC.
7
LeviFlow Splitting
Ferrite
100-30353
EMI filtering of DC supply
For LFC-6CIO-PC supply needed.
Needed on flow sensor cables, when stacking multiple converters.
8
YN-485I-TR, USB
to RS485 Adaptor-
TR Isolated
100-30392
Structure/Design
USB connector (A) with termination resistor and cable with connector
pair (B and C) for external RS485 wire connection. Magnetically
isolated. Cable length is 2m. Included is a USB space saver cable (D).
Purpose
Communication over fieldbus of converter with PC.
Table 3: Accessories
Pos.
Part Name
Part #
Flow Range
Calibration Set
Note
9a
LFSC-05D-001 + LFC-1C-PC
100-91113
0
– 1 lpm
Water @ 20°C and 37°C
Silicone and C-Flex
®
Extension and interconnect cables to be
ordered as separate article with specified
length (see
Default activated calibration set is Silicone
at 37°C water temperature.
9b
LFSC-08D-001 + LFC-1C-PC
100-91076
0
– 4 lpm
9c
LFSC-12D-007 + LFC-1C-PC
100-91012
0
– 20 lpm
9d
LFSC-22D-005 + LFC-1C-PC
100-91013
0
– 80 lpm
9e
LFSC-30D-001 + LFC-1C-PC
100-91183
0
– 160 lpm
Table 4: Standard flowmeter sets