Destination Types:
DMX p1
-DMX Output Port #1 (also p2 or p3).
LN p1
-Luma-Net port 1 or port 2
x.x.x.x
-an IP address of another ColorNet device
DMX u1
-ColorNet Universe #1, (also can be u2-u256 for
other universes).
i-ser p1
-Indicates i Series dimmer rack, port #1.
Other Nomenclature:
c
-Indicates channel. C1-48 indicates channels 1-48.
That covers most of the nomenclature. You will see it referenced
throughout the remainder of this chapter and in the next chapter
on patch manipulation.
Let’s look at a couple of examples using the information we just
learned.
From this information, we can discover that the input to DMX port
#1, channels 1-512 is patched to ColorNet Universe #1.
Now, let’s look at another example,
univ p1 c1-24 > DMX p3 c25
This patch takes ColorNet Universe #1, channels 1-24, and patches
them into the DMX output port #3 of this NPC, starting at channel