C
HAPTER
4
| Configuring the Switch
Configuring Security
– 64 –
C
ONFIGURING
SSH
Use the SSH Configuration page to configure access to the Secure Shell
(SSH) management interface. SSH provides remote management access to
this switch as a secure replacement for Telnet. When the client contacts the
switch via the SSH protocol, the switch generates a public-key that the
client uses along with a local user name and password for access
authentication. SSH also encrypts all data transfers passing between the
switch and SSH-enabled management station clients, and ensures that
data traveling over the network arrives unaltered.
P
ATH
Advanced Configuration, Security, Switch, SSH
U
SAGE
G
UIDELINES
◆
You need to install an SSH client on the management station to access
the switch for management via the SSH protocol. The switch supports
both SSH Version 1.5 and 2.0 clients.
◆
SSH service on this switch only supports password authentication. The
password can be authenticated either locally or via a RADIUS or
remote authentication server, as specified on the Auth
Method menu (
page 61
).
To use SSH with password authentication, the host public key must still
be given to the client, either during initial connection or manually
entered into the known host file. However, you do not need to configure
the client's keys.
◆
The SSH service on the switch supports up to four client sessions. The
maximum number of client sessions includes both current Telnet
sessions and SSH sessions.
P
ARAMETERS
These parameters are displayed:
◆
Mode
- Allows you to enable/disable SSH service on the switch.
(Default: Enabled)
W
EB
I
NTERFACE
To configure SSH:
1.
Click Advanced Configuration, Security, Switch, SSH.
2.
Enable SSH if required.
3.
Click Save.
Figure 16: SSH Configuration
Содержание GEP-5070
Страница 1: ...GEP 5070 48 GE PoE Plus 2 GE SFP L2 Managed Switch User Manual V1 0...
Страница 2: ......
Страница 4: ......
Страница 6: ...ABOUT THIS GUIDE 6...
Страница 18: ...FIGURES 18...
Страница 20: ...TABLES 20...
Страница 22: ...SECTION I Getting Started 22...
Страница 34: ...SECTION II Web Configuration 34...
Страница 217: ...CHAPTER 4 Configuring the Switch Configuring sFlow 217 Figure 96 sFlow Configuration...
Страница 218: ...CHAPTER 4 Configuring the Switch Configuring sFlow 218...
Страница 286: ...CHAPTER 6 Performing Basic Diagnostics Running Cable Diagnostics 286...
Страница 291: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 291 Figure 157 Configuration Upload...
Страница 292: ...CHAPTER 7 Performing System Maintenance Managing Configuration Files 292...
Страница 294: ...SECTION III Appendices 294...
Страница 312: ...GLOSSARY 312...
Страница 317: ......
Страница 318: ...GEP 5070 E042013 ST R01...