You can add XXpppp in front of each SMS message, which you received this way, change
values of required parameters and send the message back as new values of configuration.
5.29. RESET of Gate and Time Counters.
It is possible to carry out remote RESET of GB 200 by means of SMS message. Action is
equivalent to switch-on of charging tm. start-up of program, switch-off and on of GSM
module and login in network. However, in this case counters of time in operation are cleared
either.
Instruction by Phone
SMS Instruction
Pre-set
RESET
5.30. Initialisation of Gate to Initial Set-up from Production.
Remote initialisation of GB 200 can be carried out by means of SMS message. All
adjustable parameters except PINs and blocking of SIM card are set to initial values set
from production. At the same time RESET is carried out (for range of reset see chapter
5.28).
Instruction by Phone
SMS Instruction
Pre-set
INIT
SMS message as well as all other SMS instructions requires entering of heading with actual
PIN of SIM card XXpppp in front of instruction (see chapter 4.2). If you do not know this PIN
it is necessary to carry out configuration from PC or hardware initialisation in following way:
Interconnect PINs No. 9 and 10 of connector CANNON15 and simultaneously connect GB
200 to power supply. Greed LED flashes quickly and gate is in initial set-up.
6. Operation.
6.1. Outline of Tones.
Without dialling tone
Dialling tone of dial No. 1
Dialling tone of dial No. 2
Dialling tone of dial No. 3
Tone "programming"
Tone "engaged"
Ringing and tone of ringing
Warning tone
6.2. Operation during Current Outage.
It is not possible to make calls during current outage. Therefore we recommend connecting
of network supply from backed up power supply UPS or connecting of backup power supply
from battery 12V. Programmed configuration will be saved in memory - type EEPROM – for
arbitrarily long time during current outage.