6.2. 

Additional Programming Commands 

 

Additional programming commands can be entered using SMS commands (details in 
Chapter 4.2.) 

 

Description 

Command 

Range 

Defa

ult  

Complete information about device, name, 

serial number, hardware and software 

version 

PRODUCT 

 

 

Type of device 

PRONAME 

 

 

Serial number of device 

PRONUM 

 

 

Software version (firmware) 

SWVER 

 

 

Hardware version 

HWVER 

 

 

Complete information about GSM network 

connection 

GSM 

 

 

GSM operator name 

OPERATOR 

 

 

Prepaid credit for each SIM card 

CREDIT 

 

 

GSM cell ID number used by device 

CELLID 

 

 

GSM signal strength 

SIGNAL 

0= min. 36= max 

 

Complete information about binary inputs 

and outputs status 

IOS 

 

 

Find out prepaid credit for each SIM card 

CREDITMODE  x 

x= 0 do not find 

out  

x= 1 find out 

credit on SIM 

x= 2 find out 

credit by USSD 

command 

USSD command for getting the prepaid 

credit value for each SIM 

CREDITUSSD  x 

x= 0-8 symbols 

USSD command 

Lower limit of prepaid credit, reaching this 

value will result in sending a warning 

SMS 

CREDITLOW  x  

x= 0-1000000  

 

Text of SMS sent during the device reset  

RESETTXT  x  

x= 0-100 

characters 

in SMS is x in“” 

Text of SMS sent when lower limit of 

prepaid credit is reached 

CREDITTXT  x 

x= 0-100 char.  

in SMS is x in“” 

 

Содержание GB 102 122

Страница 1: ...GB 102 Series with Built in GSM Module Two way Converter of Phone Line to GSM USER GUIDE LEVEL LEVEL LEVEL LEVEL GSM GATE DAISYGATE...

Страница 2: ...1...

Страница 3: ...onnect either direct or extension phone lines to connector ATTENTION GSM Gates are not subject of homologation by T Czech Telecommunication Office Entrepreneur is therefore obliged to ensure that call...

Страница 4: ...er Is Sent 11 5 9 Set up of Dial Tone Type 12 5 10 Set up of Programming Symbol or 12 5 11 Set up of Tariffs 12 5 12 Number for Information SMS Messages 13 5 13 Set up of Number for Monthly Upkeep Cal...

Страница 5: ...001 GSM antenna 3 dB ED 102 001 Convertor with cables software for configuration Mounting set wall plugs screws and drill template Conector micro Fit 6 grip User Guide Note included in the set access...

Страница 6: ...f connecting cable for installation should not be shorter than 5 meters so that it is possible to place GSM Gate and antenna in sufficient distance from exchange However phone cable should not be long...

Страница 7: ...ximum adjustment of gate GB 102 to environment and user s requirements can be set by programming Parameter configuration change can be performed using Control Panel software connected via serial line...

Страница 8: ...al tone 2 Dial pppp where pppp are four digits of gate PIN PIN is set 1234 from production After entering correct PIN you will hear tone configuring tone 3 Enter particular setting parameters Dial 4 d...

Страница 9: ...ing of an instruction is always sent back to sender s cell phone Parameter NOTIFYSMS means that the preset number will receive all reset messages and low prepaid credit reports If parameter INFOSMS is...

Страница 10: ...number dialed before interconnection when connecting call to transmitter with GSM gate This function allows reconstruction of originally dialed number by adding of removed pre selection Dial Command...

Страница 11: ...card according to dialed number parameter SIMDIR set numbers of pre selections from longest to shortest Priority of evaluation goes from above 5 4 Code for Disallowed Directions Code for disallowed di...

Страница 12: ...nd means time in tenths of seconds tm 0 0 9 9 s 5 6 Set up of Waiting Time for Dial After picking up GSM gate gives you dialing tone which notifies you about possibility of dialing of number After set...

Страница 13: ...sion exchange for any service concurrent with functions of GSM gate it is possible to set that symbol is used exclusively in all instructions instead of symbol Dial Command SMS Command Default 1100x F...

Страница 14: ...Default 2100x MCALL x Not activated from production Where x is 1 to 20 digits of number Removal of values is carried out by instruction 2100 or by SMS message MCALL point represents data If you want...

Страница 15: ...5 16 Set up of Numbers for ALARM Calling When one of the inputs 1 5 is activated only GB 102 x2x the preset phone number will be dialed and the called party will hear warning tone from GB 102 first th...

Страница 16: ...s required logical level of 0 or 1 Recommended linkage of outputs with galvanic detachment example for output No 1 Drawing of connector on GB 102 5 19 Set up of Sensitivity of Audio Input Instruction...

Страница 17: ...eature and x 0 disables the feature Delay of Additional DTMF Transmission This parameter determines the delay before the additional DTMF selection starts after the phone call is answered Additional DT...

Страница 18: ...s suitable for directing phone calls to PBX s with ISDN dialing in Mode 1 additional dial will replace the enter prefix dial of short code selection coming to the gateway with phone number of the resu...

Страница 19: ...out Implementation of INIT makes GSM Gate during 20 sec If you are doing this implementation through the phone hang up after return dialing tone in the phone receiver Dial Command SMS Command Default...

Страница 20: ...3 x ADIR4 x ADIR5 x ADIR6 x ADIR7 x ADIR8 x ADIR9 x ADIR10 x ADIR11 x ADIR12 x ADIR13 x ADIR14 x ADIR15 x ADIR16 x x 1 7 digits or x clears out parameter value 1 2 3 4 5 6 7 8 9 0 Code for disallowed...

Страница 21: ...Alarmx Set up of outputs 260xy IOx y x input 1 5 y 0 or 1 all 1 Setting audio in 2701x AUDIOINP x x 0 100 64 Setting audio out 2702x AUDIOOUT x x 0 100 64 Virtual tie line DTMF pulse width 3000x TIEWI...

Страница 22: ...cell ID number used by device CELLID GSM signal strength SIGNAL 0 min 36 max Complete information about binary inputs and outputs status IOS Find out prepaid credit for each SIM card CREDITMODE x x 0...

Страница 23: ...ts automatically you can also run the setup exe file on the CD Please follow the installation guide dialog 7 2 Control Panel Program answers the purpose of comfortable and transparent configuration of...

Страница 24: ...ector RJ 11 SMS inputs micro Fit No 1 5 log 0 0 0 5 V log 1 2 5 V SMS outputs micro Fit No 1 5 log 0 max 0 4 V max Iz 5 mA log 1 2 3 3 V at Iz 0 1mA micro Fit 12 V DC max load 200 mA GSM network GSM 9...

Страница 25: ...24 GUARANTEE CERTIFICATE Product name Type Production number Date of sale Signature Seller Address Phone Stamp Date of Receipt Date of Shipping Description of Defect...

Страница 26: ...ee Certificate damage of product caused by natural disaster during transport by unsuitable positioning unsuitable handling and operation of device in unsuitable conditions or in case of damage or remo...

Страница 27: ...26...

Страница 28: ...27 GB 102 2xx 1 03 LEVEL 2005 LEVEL Ltd Plhovsk 1997 N chod 547 01 CZECH REPUBLIC www levelna cz...

Отзывы: