14
Recommended linkage of input, example for input No. 1.
(Drawing of connector on GB 102)
Since output works at the same time also as input set-up of logical level 0 on
output avoids activation of sending SMS message from particular input.
In case call is just made through GB 102 it is terminated immediately and all
alarm actions are carried out.
5.15.
ALARM SMS Messages and Set-up of B-numbers for SMS Sending
Instruction by Phone
SMS Instruction
Pre-set
220xy#
SMSNOBx y
Not activated in production
Where x is number of input from 1 to 5.
Where y is 1 to 20 digits of cell phone number.
5.16.
Set-up of Numbers for ALARM Calling
When one of the inputs 1-5 is activated (only GB 102 x2x), the preset phone
number will be dialed and the called party will hear warning tone from GB 102 -
first three DTMF tones followed by number of further tones, that number is
determined by number of the activated input..
Instruction by Phone
SMS Instruction
Pre-set
240xy#...
ALARMCALLx y
Not activated in production
Where x is number of input No. 1-5.
Where y is 1 to 20 digits of number to any phone.
5.17.
Set-up of Text of ALARM SMS Messages
Set text of message, which is sent in case of input activation, is assigned to
particular input No. 1-5 (only GB 102 x2x). Text can be changed by following
instruction:
Instruction by Phone
SMS Instruction
Pre-set
250xtext#...
SMSTXTx “text“
Set from production: ALARMx