22
8. Technical data
MSI 200
Connection method
Pluggable screw terminal block
Order No.
MSI 201
547 803
Pluggable spring-cage terminal block
Order No.
MSI 202
547 813
Logic
Nominal input voltage U
N
24 V DC (A1/A2)
Permissible range
0.85 - 1.1 x U
N
Typ. current consumption at U
N
110 mA
Maximum response time
< 30 ms
Voltage dip bridging
20 ms
Recovery time restart
< 10 s
Diagnostic and status indicator
4 LEDs (green, red)
Inputs (IN)
Number of safe inputs
20 (up to SIL 3/EN 62061)
Nominal voltage
24 V DC
Typ. current consumption at U
N
4 mA
Signal level at "0"
< 5 V
Signal level at "1"
> 11 V
Max. line length (total)
2000 m
Error detection time at 1-channel structure
< 1 s
Diagnostic and status indicator
20 LEDs (green)
Output data
Safe semiconductor outputs
4 (Cat. 4/EN ISO13849-1/EN 954)
Ground switching outputs
2
Nominal voltage
24 V DC (24 V/0 V)
Permissible range
0.85 - 1.1 x U
N
Limiting continuous current
2 A (see derating)
Load
- capacitive load
1)
max.
- inductive load
2)
1
μ
F (electronic components)
-
Switch-off pulses
< 1 ms
Short-circuit protection
Yes
Diagnostic and status indicator
4 LEDs (green)
Clock outputs
Number
2
Nominal voltage
24 V DC (A1/A2)
Limiting continuous current
100 mA
Test pulses
< 1 ms
Short-circuit protection
Yes
Monitoring outputs
Number
4
Nominal voltage
24 V DC (A1/A2)
Limiting continuous current
100 mA
Short-circuit protection
Yes
General data
Permissible ambient temperature
Operation
- 20 °C to 55°C
Storage
- 20 °C to 70°C
Nominal operating mode
100% operating factor
Degree of protection according to
Housing
VDE 0470 Part 1
Connection terminal blocks
Installation location
IP20
IP20
Minimum IP54