background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

HTU330-3500…-M12 - 01

[email protected]  •  www.leuze.com

HTU330-6000…-M12 - 01

Part number code

Order guide

The sensors listed here are preferred types; current information at www.leuze.com.

2

H T U 3 3 0 - 3 5 0 0 . 3 / 4 P K - M 1 2

Operating principle
HTU

Ultrasonic sensor, scanning principle, 

with background suppression

DMU Ultrasonic sensor, distance measurement
RKU

Ultrasonic sensor, retro-reflective ultrasonic sensor

Series
330

330 series, cylindrical short M30 design

Scanning range in mm
3500 250 … 3500
6000 350 … 6000

Equipment
.3

Teach button on the sensor

Pin assignment of connector pin 4 / black cable wire (OUT1)
4

PNP output, NO contact preset

P

PNP output, NC contact preset

2

NPN output, NO contact preset

N

NPN output, NC contact preset

Pin assignment of connector pin 2 / white cable wire 

(Analog OUT/OUT2)
4

PNP output, NO contact preset

P

PNP output, NC contact preset

2

NPN output, NO contact preset

N

NPN output, NC contact preset

C

Analog output 4 … 20mA

V

Analog output 0 … 10V

Pin assignment of connector pin 5 / gray cable wire (Sync / MUX)
K

Synchronization/multiplex input

Connection technology
M12

M12 connector, 5-pin

Designation

Part no.

Scanning range / switching output / teach-in

250 … 3500mm / 2 x PNP / teach button

HTU330-3500.3/4PK-M12

50136110 

250 … 3500mm / 2 x NPN / teach button

HTU330-3500.3/2NK-M12

50136111 

350 … 6000mm / 2 x PNP / teach button

HTU330-6000.3/4PK-M12

50136116 

HTU330

Ultrasonic sensors with 2 switching outputs

Содержание HTU330 Series

Страница 1: ... point can be taught NO NC function reversible 2 independent switching outputs PNP or NPN NEW Both outputs can easily be taught using a button NEW Stable plastic design NEW Temperature compensated scanning range 250 3500mm 350 6000mm Accessories available separately Mounting systems Cables with M12 connector KD Dimensioned drawing A Active sensor surface B Teach in button C Indicator diodes DMU330...

Страница 2: ... Plastic PBT Active surface Epoxy resin glass fiber reinforced Weight 140g 170g Ultrasonic transducer Piezoceramic 7 7 The ceramic material of the ultrasonic transducer contains lead zirconium titanate PZT Connection type M12 connector 5 pin Fitting position Any Environmental data Ambient temp operation storage 20 70 C 20 70 C Protective circuit 8 8 1 short circuit and overload protection 2 polari...

Страница 3: ...connector pin 4 black cable wire OUT1 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset Pin assignment of connector pin 2 white cable wire Analog OUT OUT2 4 PNP output NO contact preset P PNP output NC contact preset 2 NPN output NO contact preset N NPN output NC contact preset C Analog output 4 20mA V Analog output 0 10V Pi...

Страница 4: ...LED OFF Green LED ON Distance Hysteresis Switching point Scanning range OUT not active Yellow blue LED OFF Green LED OFF OUT not active Yellow blue LED OFF Green LED OFF Dead zone Sensor OUT not active Yellow blue LED OFF Green LED ON OUT active Yellow blue LED ON Green LED OFF Distance Hysteresis Switching point Scanning range OUT active Yellow blue LED ON Green LED OFF OUT active Yellow blue LED...

Страница 5: ...ior with 2 point window teach as a function of the switching function 1 Place object at desired switching distance 1 First place object at desired switching distance for switching point 1 2 To adjust the selected output press the teach button for 2 7s until the yellow LED OUT 1 or blue LED OUT 2 flashes at 3Hz The current state of the selected output is frozen during the adjustment process 2 To ad...

Страница 6: ...d the switching output is changed to the opposite state toggled First activate the previously described teach mode for output OUT 1 or OUT 2 Changeover of the switching function 1 To change the switching function of the selected output press the teach button for longer than 12s The current state of the selected output is frozen during the adjustment process 2 The green and yellow blue LEDs flash a...

Страница 7: ...gram A synchronization pulse from the control activates synchronous operation The devices work in synchronous operation with a simultaneous transmission pulse The response time of the individual sensors in the network corresponds approximately to that of a single sensor Synchronous operation wiring schematic Timing diagram for synchronous operation Working distance Minimum mounting distance 1 500m...

Страница 8: ...ease the button The green yellow and blue LEDs flash alternately and very quickly for a brief time The sensor was reset to the factory setting switching output OUT 1 NO contact 1 switching point at 3500 mm or 6000 mm static 1 point teach switching output OUT 2 NC contact 1 switching point at 3500 mm or 6000 mm static 1 point teach Sensor 2 Sensor 1 Sensor n NOTE Please make certain that the wiring...