SSI interface
Leuze electronic GmbH + Co. KG
AMS 307
i
53
TNT
35/7-2
4V
9.1.1
SSI sequence diagram
Figure 9.1: SSI data transmission sequence diagram
Note!
In the default setting, the LSB bit is the error bit.
Attention!
Significance of the error bit:
By default, a 25th error bit (LSB) is appended to the 24-bit measurement value.
The error bit is not included in the Gray encoding of the measurement value.
The error bit is 1 = active, 0 = not active.
Note!
The data can be read out at a clock rate between 80kHz and 800kHz.
Attention!
Updating the measurement values on the SSI interface of the
AMS 307
i
:
The measurement value on the SSI interface of the
AMS 307
i
is updated approx. every 1.7ms
(default) irrespective of the clock frequency.
The update rate on the interface can be reduced to 0.2ms via the display under the SSI menu
item.
Clock sequence
Complete transmission cycle