Display and control panel AMS 307i
46
AMS 307
i
Leuze electronic GmbH + Co. KG
I/O submenu
Error delay
ON/OFF
Specifies whether, in the event of an error, the position value
immediately outputs the value of the "Position value in the
case of failure" parameter or the last valid position value for
the configured error delay time.
ON/100
ms
Position value
in the case of
failure
Last valid value / zero
Specifies which position value is output after the error delay
time elapses.
Zero
Table 8.4:
I/O submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
I/O 1
Port con
-
figuration
Input/Output
Defines whether I/O 1 functions as an output or input.
Output
Switching
input
Function No function/teach preset/laser ON/OFF
No function
Activa
-
tion
Low active/High active
Low active
Switching
output
Function Pos. limit value 1 / Pos. limit value 2 / Velocity /
Intensity (ATT) / Temp. (TMP) / Laser (LSR) /
Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected
switching output.
Plausibility
(PLB), hard
-
ware (ERR)
Activa
-
tion
Low active/High active
Low active
I/O 2
Port con
-
figuration
Input/Output
Defines whether I/O 2 functions as an output or input.
Output
Switching
input
Function No function/teach preset/laser ON/OFF
No function
Activa
-
tion
Low active/High active
Low active
Switching
output
Function Pos. limit value 1 / Pos. limit value 2 / Velocity /
Intensity (ATT) / Temp. (TMP) / Laser (LSR) /
Plausibility (PLB) / Hardware (ERR)
The individual functions are "ORed" on the selected
switching output.
Intensity (ATT),
Temp. (TMP),
Laser (LSR)
Activa
-
tion
Low active/High active
Low active
Limit values
Upper
pos.
limit 1
Activa
-
tion
ON/OFF
OFF
Limit
value
input
Value input in mm or inch/100
0
Lower
pos.
limit 1
Activa
-
tion
ON/OFF
OFF
Table 8.3:
Position value submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard