Starting up the device - RS 485 Modbus interface
Leuze electronic GmbH + Co. KG
CML 730i
149
Overview
System commands (group 1)
CML 700i status information (group 2)
The following abbreviations for data types apply in the following module descriptions:
t08U = type: 8 bit, unsigned CHAR
t08S = type: 8 bit, signed CHAR
t16U = type: 16 bit, unsigned SHORT
t16S = type: 16 bit, signed SHORT
Group
Group name
Group 1
System commands (see page 149)
Group 2
CML 700i status information (see page 149)
Group 3
Device description (see page 150)
Group 4
General configurations (see page 151)
Group 5
Extended settings (see page 151)
Group 6
Process data settings (see page 152)
Group 7
Cascading/trigger settings (see page 152)
Group 8
Blanking settings (see page 153)
Group 9
Group 10
Digital IO pin N settings (N = 2. 5) (see page 154)
Group 11
Time module settings for digital outputs (see page 155)
Group 12
Configuration for block evaluation of beam areas (see page 156)
Group 13
Evaluation functions (see page 158)
The system commands trigger a direct action in the CML 700i.
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Command
84
4 bytes
t16U
RW
1 … 8
1: Reserved
2: Reserved
3: Teach
4: Reboot
5: Reset
6: Save settings
Note:
Processing of the Save command takes up to
600 ms. During this time, no other data/telegrams
are accepted.
The CML 700i status information specifies operating state information or error messages.