Starting up the device - RS 485 Modbus interface
Leuze electronic GmbH + Co. KG
CML 730i
155
Settings for digital switching outputs (group 11)
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Switching level of inputs/
outputs
4D
4 bytes, switch
-
ing level configu
-
ration of inputs/
outputs
t08U
RW
0 … 1
1
Switching level of the inputs/outputs
0: Transistor, NPN
1: Transistor, PNP
Note on the data structure:
0x00000000, 0x00010000,0x00020000
The last two bytes are filler bytes and are ignored
Keyboard lock
4E
2 bytes keyboard
lock configuration
t08U
RW
0 … 2
Note on the data structure:
2 bytes in format 0xYZ 0xFF
The byte with the lower value is a filler byte and is
ignored.
YZ=00/01/02
0: No lock
1: Persistable lock
2: Volatile lock
Examples
• ReadRequest send string (read access)
01 03 00 4E 00 01 E4 1D
• ReadRequest response string (response to
read access)
01 03 02 00 FF F8 04
• WriteRequest send string (write access):
01 10 00 4E 00 01 02 00 FF E9 FE
• WriteRequest response string (response to
write access):
01 10 00 4E 00 01 61 DE
Configuration of pin 2
Digital IO Pin 2 Settings
50
4 bytes,
configuration IO1
RW
Input/output selection
50
t08U
RW
0 … 1
0
0: Output
1: Input
Switching behavior
50
t08U
RW
0 … 1
0
0: Not active (normal - light switching)
1: Active (inverted - dark switching)
Input function
50
t08U
RW
0 … 2
0
0: Not active
1: Trigger input (Trigger In)
2: Teach input (Teach In)
Output function
50
t08U
RW
0 … 3
0
0: Not active
1: Switching output (area 1 … 32)
2: Warning output
3: Trigger output
Configuration of pin 5
Digital IO Pin 5 Settings
51
4 bytes,
configuration IO2
RW
Input/output selection
51
t08U
RW
0 … 1
0
0: Output
1: Input
Switching behavior
51
t08U
RW
0 … 1
0
0: Not active (normal - light switching)
1: Active (inverted - dark switching)
Input function
51
t08U
RW
0 … 2
0
0: Not active
1: Trigger input (Trigger In)
2: Teach input (Teach In)
Output function
51
t08U
RW
0 … 3
0
0: Not active
1: Switching output (area 1 … 32)
2: Warning output
3: Trigger output
Four different time functions can be configured in this group.
Map the output to areas 1 … 32. Activate the area by entering a 1 at the corresponding position
in the 32-bit word. Area 1 … 32 increasing from right.