Starting up the device - RS 485 Modbus interface
Leuze electronic GmbH + Co. KG
CML 730i
151
General configurations (group 4)
Extended settings (group 5)
Transmitter part number
42
20-byte string with
the part number
of the transmitter
string
20 byt
es
RO
Transmitter order number (8-digit)
Transmitter serial num
-
ber
43
16-byte string with
the transmitter
serial number
string
16 byt
es
RO
Transmitter serial number for unique product iden
-
tification
Device description
44
10-byte string with
the device
description
string
10 byt
es
RO
The device characteristics specify the beam spac
-
ing, the number of physical/logical individual
beams, the number of cascades (16 individual
beams) in the device and the cycle time.
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Configured under group 4 “General configurations” are the type of scanning (parallel-/diagonal-
/crossed-beam), counting direction and the minimum object diameter for the evaluation (smooth
-
ing). The minimum hole size for the evaluation, e.g., with web material, is configured via inverted
smoothing.
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
General settings
47
4 bytes with the
general settings
RW
Beam mode
47
t08U
RW
0 … 3
0
Beam mode
0: Parallel-beam scanning
1: Diagonal-beam scanning
2: Crossed-beam scanning
3: Beam matrix
Counting direction
47
t08U
RW
0 … 1
0
Counting direction
0: Normal – starting with the connection piece
1: Inverted – ending with the connection piece
Smoothing
47
t08U
RW
1 … 255
1
Smoothing:
Less than i interrupted beams are ignored.
InvertedSmoothing
47
t08U
RW
1 … 255
1
Inverted smoothing:
Less than i free beams are ignored.
The extended settings specify the autoteach function, filter depth (with respect to the number of
interrupted beams as switching trigger) and integration time (hold function).
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Extended settings
4A
4 bytes with the
extended settings
RW
Autoteach
4A
t08U
RW
0 … 1
0
0: Not active
1: Active
Filter depth
4A
t08U
RW
0 … 255
1
The filter depth indicates the necessary number of
consistent beam states before the evaluation of
the measurement values. The filter depth corre
-
sponds to the number of passes with interrupted
beam so that the result leads to switching.
Integration time
4A
t16U
RW
0 … 6553
5
0
All measurement values are accumulated and
retained over the duration of the integration time.
Hold function in ms