Starting up the device - RS 485 Modbus interface
Leuze electronic GmbH + Co. KG
CML 730i
156
Configuration for block evaluation of beam areas (group 12)
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Configuration of switch
-
ing output pin 2
54
4 bytes, configu
-
ration output 1
RW
Four different time functions can be set. Max.
adjustable time period is 65 sec. Output has to be
assigned to a beam area 1 … 32.
Operating mode of time
module
54
t08U
RW
0 … 4
0
0: Not active
1: Start-up delay
2: Switch-off delay
3: Pulse stretching
4: Pulse suppression
Time constant for
selected function
54
t16U
RW
0 … 6553
5
0
Unit: ms
Area mapping
54
t32U
RW
0 … 4294
967295
1: For
DO1
2: For
DO2
4: For
DO3
8: For
DO4
Logical OR link mask of the switching outputs
Digital switching output
pin 5
55
4 bytes, configu
-
ration output 2
RW
Four different time functions can be set. Max.
adjustable time period is 65 sec. Output has to be
assigned to a beam area 1 … 32.
Operating mode of time
module
55
t08U
RW
0 … 4
0
0: Not active
1: Start-up delay
2: Switch-off delay
3: Pulse stretching
4: Pulse suppression
Time constant for
selected function
55
t16U
RW
0 … 6553
5
0
Unit: ms
Area mapping
55
t32U
RW
0 … 4294
967295
1: For
DO1
2: For
DO2
4: For
DO3
8: For
DO4
Logical OR link mask of the switching outputs
In this group, a detailed area configuration can be displayed and a beam area configured for the
block evaluation.
Parameter
Index
(hex.)
Response
Data
type
Access Value
range
Default Explanation
Configuration of area 01
64
14 bytes info
area 01
RW
Configuration of area 01: definition of the status
conditions so that the area takes on a logical 1
or 0. For diagonal- or crossed-beam mode, the
numbers of the logical beams are to be entered.
Area
64
t08U
RW
0 … 1
0
0: Not active
1: Active
Active beam
64
t08U
RW
0 … 1
0
0: Light switching (beam is active if light path is
free)
1: Dark switching (beam is active if light path is
interrupted)
Start beam of area
64
t16U
RW
1 … 1774
65534
65533
65532
65531
1
Dynamic start positions are created by means of
entries in the form of impossible beam numbers.
65534: First interrupted beam (FIB)
65533: First not interrupted beam (FNIB)
65532: Last interrupted beam (LIB)
65531: Last not interrupted beam (LNIB)
End beam of area
64
t16U
RW
1 … FFE
E
1
Number of active beams
for area ON
64
t16U
RW
0 … 1774 0