Communicating with the Device
Leuze electronic
VR 2300
59
TNT
35/7-2
4
V
mode (see also chapter 9.3.17 on page 52). The error
string may have a maximum of 7 characters.
"Trigger on" command
Defines the character string that trips a serial trigger. (see
also chapter 9.3.17 on page 52). The string must not be
longer than 7 characters and must be framed by header
and terminator during transmission.
"Trigger off" command
Defines the character string that terminates a serial
trigger. The string must not be longer than 7 characters
and must be framed by header and terminator during
transmission.
"Get code" command
Defines the character set which requests the output of a
read code. The string must not be longer than 7 charac-
ters and must be framed by header and terminator during
transmission.
Automatic code transmission
Permits a newly-read code to be output immediately via
the interface, without a
"Get code" command
having
been sent.