Electrical Installation
42
TMC 66
Leuze electronic
DEUTSCH
E
NGLISH
FRANÇAIS
IT
A
LIANO
ESPAÑOL
N
EDERLANDS
Muting phase 2
Activation of muting through interruption of Start 1
The indicator diode for "Start 1" goes off, the LEDs for "Control 1" and "Control 2" remain
active.
The 7-segment display changes from "22" to "23".
Muting phase 3
The single beam safety light barrier is interrupted.
The indicator diode for "Sensor" goes off, the LEDs for "Control 1" and "Control 2" remain
active.
The 7-segment display changes from "23" to "33". Through this is displayed that the safety
outputs are closed although the single beam safety light barrier is interrupted.
Fig. 5.14-2:
Muting phase 2
Fig. 5.14-3: Muting phase 3
Hazardous area
Protective photo
electric sensor
Start 1
Start 2
Hazardous area
Protective photo
electric sensor
Start 1
Start 2