Leuze electronic GmbH + Co. KG
In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0
[email protected] • www.leuze.com
6
Diagnosis in the event of an error
Table 4
7
Cleaning and storage
A damp cloth can be used for cleaning of the device housing.
Store in a clean, temperature-regulated and dry place!
Error
Possible cause
Remedial measures
POWER
LED does not light up green
No input voltage
Check voltage supply
No edge detection possible
(
EDGE
LED not illuminated)
Working distance too great
Check working distance and adapt as necessary
(section 3.2)
No calibration performed
Perform calibration procedure (section 4.1)
Sensitivity not ideal
Perform setting procedure (sections 4.3 or 5)
Direction of overlap flow/direction of movement
incorrect
Check settings (section 3.3)
Object to be counted not suitable
Test with reference (section 3)
No laser beam (
Caution! Refer to the laser safety
notices in section 8!
)
Notify the manufacturer
Edge counting faulty
Sensitivity/calibration not ideal, influence of ambient
light
Readjust sensitivity (sections 4.3 or 5) /
repeat calibration procedure (section 4.1)
Error due to multiple pulses
Check pulse width adjustment and readjust /
run
DPA
program (recommended) as necessary
Objects to be counted not ideal
Test with reference
Sequential speed of edges outside of specification
Check period following object, perform a test at low
speed
The output pulse width can only be
adjusted in minimum range
Incorrect range mode set
Switch mode over to desired range (section 4.5)
No output pulse, although
EDGE
LED is
detecting an edge
Contact problem
Check connection cable
Notice!
Faulty results due to changes within the overlap flow with regard to color change, surface structure and edge shape of the
objects to be counted or the distance of the objects from the detector may necessitate renewed calibration and resetting of
the device to the new conditions, and do not necessarily relate directly to malfunctioning of the device.
Attention!
The optics cover (laser beam emission) on the underside of the device may only be cleaned with a non-scratch cloth specially
designed for cleaning lenses (micro-fiber cloth)!
OPSL 775