background image

Leuze electronic GmbH + Co. KG

In der Braike 1 D-73277 Owen Tel. +49 (0) 7021 573-0

OPSL 775/4-150-S12 - 03

[email protected]  •  www.leuze.com

6

Diagnosis in the event of an error

Table 4

7

Cleaning and storage

A damp cloth can be used for cleaning of the device housing. 

Store in a clean, temperature-regulated and dry place!

Error

Possible cause

Remedial measures

POWER

 LED does not light up green

No input voltage

Check voltage supply

No edge detection possible
(

EDGE

 LED not illuminated)

Working distance too great

Check working distance and adapt as necessary 
(section 3.2)

No calibration performed

Perform calibration procedure (section 4.1)

Sensitivity not ideal

Perform setting procedure (sections 4.3 or 5)

Direction of overlap flow/direction of movement 
incorrect

Check settings (section 3.3)

Object to be counted not suitable

Test with reference (section 3)

No laser beam (

Caution! Refer to the laser safety 

notices in section 8!

)

Notify the manufacturer

Edge counting faulty

Sensitivity/calibration not ideal, influence of ambient 
light

Readjust sensitivity (sections 4.3 or 5) /
repeat calibration procedure (section 4.1)

Error due to multiple pulses

Check pulse width adjustment and readjust / 
run 

DPA

 program (recommended) as necessary

Objects to be counted not ideal

Test with reference

Sequential speed of edges outside of specification

Check period following object, perform a test at low 
speed

The output pulse width can only be 
adjusted in minimum range

Incorrect range mode set

Switch mode over to desired range (section 4.5)

No output pulse, although 

EDGE

 LED is 

detecting an edge

Contact problem

Check connection cable

Notice!

Faulty results due to changes within the overlap flow with regard to color change, surface structure and edge shape of the 
objects to be counted or the distance of the objects from the detector may necessitate renewed calibration and resetting of 
the device to the new conditions, and do not necessarily relate directly to malfunctioning of the device.

Attention! 

The optics cover (laser beam emission) on the underside of the device may only be cleaned with a non-scratch cloth specially 
designed for cleaning lenses (micro-fiber cloth)!

OPSL 775

Laser edge detector

Содержание OPSL 775

Страница 1: ...ection of individual sheets from 0 1mm thickness Detection range 5 150mm Adjustable pulse stretching Dynamic output pulse adaptation DPA Simple mounting 5 150mm 12 30 V DC Accessories available separa...

Страница 2: ...nput CAL 12 30VDC Indicators Green LED POWER ready Yellow LED EDGE edge detected internally Yellow LED STATUS output pulse edge LED yellow STATUS off flashing calibration process in progress standby m...

Страница 3: ...l times over Commonly known as multiple pulses these can occur with a single object when for example print copies are being conveyed with the open edge and not the spine edge leading Likewise interfer...

Страница 4: ...process See section 4 1 for details The settings will be saved even after power off power on Control button for dynamic pulse adaptation DPA Pressing this button will activate deactivate the dynamic p...

Страница 5: ...irection see section 8 3 2 Mounting Working distance and direction of overlap flow Fig 3 OPSL 775 Working ranges 3 3 Direction of overlap flow and direction of overlap The device will only be capable...

Страница 6: ...t 3 Press the CAL calibration button briefly once 50ms The status display is illuminated momentarily for the duration of the calibration procedure ALTERNATIVE Apply a high signal 12 30VDC for a period...

Страница 7: ...is saved permanently Dynamic pulse adaptation is only suitable for relatively regular edge distances example printing of newspapers The program adapts the output pulse width permanently to the period...

Страница 8: ...etection of multiple pulses Through an extension of the output pulse width these interference pulses are selectively suppressed and thus counting reliability is increased The desired output pulse widt...

Страница 9: ...the changeover procedure when changing the range mode DPA active 1 LED 0 2 2 Factory setting 0 5 512 1 0 5 128 2 0 5 32 3 0 5 8 Attention If no button is actuated within 8s of calling up the function...

Страница 10: ...Counting result correct NO YES End Counting result correct NO YES Edge detection possible NO YES Adjust Sens potentiometer to the left right Adjust pulse width potentiometer to the left right Repeat...

Страница 11: ...ideal influence of ambient light Readjust sensitivity sections 4 3 or 5 repeat calibration procedure section 4 1 Error due to multiple pulses Check pulse width adjustment and readjust run DPA program...

Страница 12: ...erformance of procedures other than specified herein may result in hazardous light exposure Adhere to the applicable legal and local regulations regarding protection from laser beams The device must n...

Отзывы: