OPSL 775/4-150-S12 - 03

2015/12

Specifications

Optical data

Measurement range 

1)

1) For objects with a luminosity coefficient of 18 … 90%

5 … 150mm

Edge height

0.1mm

Focus range

100 ± 10mm for 

0.1mm edge height

Standard range

10 … 90mm/110 … 140mm for 

0.3mm edge height

Threshold

5 … 10mm/140 … 150mm for 

0.4mm edge height

Light source

laser, pulsed

Laser class

2 in accordance with IEC 60825-1:2014 

Wavelength

670nm (visible red light)

Max. Output power 

2)

2) Average value

< 1mW

Pulse duration 

3)

3) Typical value

8.3μs

Timing

Counting rate 

4)

4) Dependent upon edge height, color and surface structure of the object to be detected. 

max. 1000 copies/s

Object speed

7m/s for 0.1mm edge height, 

11m/s for 

0.4mm edge height

Object sequence distances (overlap flow)

> 1mm

Pulse width adjustment

0.5 … 512ms, fixed pulse width, 
adjustable with 270° potentiometer

Dynamic pulse adaptation

12.5 … 50%

Delay before start-up

1.2s

Electrical data

Operating voltage U

B

12 … 30VDC (incl. residual ripple) 

Residual ripple

15% of U

B

Open-circuit current

100mA

Switching output

…/4…

pin 4: PNP, activated when edge detected

Signal voltage high/low

(U

B

-2V)/

2V

Output current

max. 30mA

Sensitivity

adjustable, 270° potentiometer

Calibration input CAL

12 … 30VDC

Indicators

Green LED POWER

ready

Yellow LED EDGE

edge detected internally

Yellow LED STATUS

output pulse edge

LED yellow STATUS off/flashing

calibration process in progress/standby mode

LED yellow DPA

dynamic pulse adaptation activated

Mechanical data 

Housing

aluminum

Color

black anodized

Optics cover

glass

Fastening

dovetail or
2 M6 screws in place of the profile strip

Weight 690g
Connection type 

5-pin M12 connector

Environmental data

Ambient temp. (operation/storage)

-5°C … +55°C  / -30°C … +70°C

Protective circuit 

5)

5) 1=transient protection, 2=polarity reversal protection, 3= short-circuit protection for transistor output

1, 2, 3 

VDE safety class

III

Protection class 

IP 54

Standards applied

IEC 60947-5-2

Attention! 

It is imperative that the laser safety notices in section 8 are observed

Order guide

Designation

Part No.

Laser edge detector

OPSL 775/4-150-S12

50115063

Tables

Diagrams

0,4

0,3

0,1

110

90

10

5

150

140

0,3

0,4

Mi

nimum edge 

height [mm]

Me

asu

remen

t r

ange

 [m

m]

Remarks

Function 
characteristics:

The OPSL 775 edge detector 
is an optoelectronic sensor 
for the contactless detection 
of object edges.

Operate in accordance with
intended use!

This product is not a safety sensor 
and is not intended as personnel 
protection.

The product may only be put into 
operation by competent persons.

Only use the product in accor-
dance with the intended use.

OPSL 775

Содержание OPSL 775

Страница 1: ...ection of individual sheets from 0 1mm thickness Detection range 5 150mm Adjustable pulse stretching Dynamic output pulse adaptation DPA Simple mounting 5 150mm 12 30 V DC Accessories available separa...

Страница 2: ...nput CAL 12 30VDC Indicators Green LED POWER ready Yellow LED EDGE edge detected internally Yellow LED STATUS output pulse edge LED yellow STATUS off flashing calibration process in progress standby m...

Страница 3: ...l times over Commonly known as multiple pulses these can occur with a single object when for example print copies are being conveyed with the open edge and not the spine edge leading Likewise interfer...

Страница 4: ...process See section 4 1 for details The settings will be saved even after power off power on Control button for dynamic pulse adaptation DPA Pressing this button will activate deactivate the dynamic p...

Страница 5: ...irection see section 8 3 2 Mounting Working distance and direction of overlap flow Fig 3 OPSL 775 Working ranges 3 3 Direction of overlap flow and direction of overlap The device will only be capable...

Страница 6: ...t 3 Press the CAL calibration button briefly once 50ms The status display is illuminated momentarily for the duration of the calibration procedure ALTERNATIVE Apply a high signal 12 30VDC for a period...

Страница 7: ...is saved permanently Dynamic pulse adaptation is only suitable for relatively regular edge distances example printing of newspapers The program adapts the output pulse width permanently to the period...

Страница 8: ...etection of multiple pulses Through an extension of the output pulse width these interference pulses are selectively suppressed and thus counting reliability is increased The desired output pulse widt...

Страница 9: ...the changeover procedure when changing the range mode DPA active 1 LED 0 2 2 Factory setting 0 5 512 1 0 5 128 2 0 5 32 3 0 5 8 Attention If no button is actuated within 8s of calling up the function...

Страница 10: ...Counting result correct NO YES End Counting result correct NO YES Edge detection possible NO YES Adjust Sens potentiometer to the left right Adjust pulse width potentiometer to the left right Repeat...

Страница 11: ...ideal influence of ambient light Readjust sensitivity sections 4 3 or 5 repeat calibration procedure section 4 1 Error due to multiple pulses Check pulse width adjustment and readjust run DPA program...

Страница 12: ...erformance of procedures other than specified herein may result in hazardous light exposure Adhere to the applicable legal and local regulations regarding protection from laser beams The device must n...

Отзывы: