Configuration / Parameter Setting
#Leuze electronic
GmbH + Co KG, Postfach 11 11, D-73277 Owen/Teck, In der Braike1, D-73277 Owen/Teck, Tel. ++49 (0)7021/5730, Fax ++49 (0)7021/573199
Date: 01.07.2003
LZ - ELE - BA - GB - 0009 - 00
Page 33 of 42
4.1.2.4 Object 6504h - Supported alarms
Object 6504h contains the information on supported alarms by the laser.
Structure of parameter
Unsigned16, Read
Bit
Function
Bit = 0
Bit = 1
0 Intensity
No
Yes
1 Temperature
No
Yes
2 Hardware
No
Yes
3
Laser diode switched off
No
Yes
4 Intensity
warning
No
Yes
5 - 13 Reserved for further use
14 - 15 Manufacturer specific functions
4.1.2.5 Object 6505h - Warnings
This object is not supported.
By read access the value is always "0" .
4.1.2.6 Object 6506h - Supported warnings
This object is not supported.
By read access the value is always "0" .
4.1.2.7 Object 6507h – Software version
This object contains the software version which is implemented in the laser. It is
combined to a revision number and an index. The version-no. is indicated in ASCII
code.
e.g.: Version:
2.12
Binary:
0011 0010 0010 1110 0011 0001 0011 0010
Hex:
32 2E 31 32
Structure of parameter
Unsigned32, Read
Software version
Byte 0
Byte 1
Byte 2
Byte 3
2
7
to 2
0
2
15
to 2
8
2
7
to 2
0
2
15
to 2
8
Содержание OMS2/120 CAN
Страница 43: ......