3.2.4.12 Object 100Dh: Life Time Factor
The life time factor multiplied with the guard time gives the life time for the node
guarding protocol. If the result is "0", no node guarding is supported.
Unsigned8, Read/Write
Life Time Factor
Byte 0
2
7
to 2
0
3.2.4.13 Object 100Eh: Node Guarding Identifier
The identifier is used for the node guarding and the life guarding procedure.
Unsigned32, Read
MSB LSB
31 30 29 28-11
10-0
reserved
0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 bit identifier
Bit 10 - 0 = 11 bit identifier, value = 700h + Node-ID
3.2.4.14 Object 1010h: Store Parameters
This object supports the saving of parameters in non volatile memory (EEPROM).
Index Sub-Index Comment
Type
1010h
0
largest supported sub-index
Unsigned8
1
save all parameters
Unsigned32
Sub-index0:
The entry in sub-index 0 contains the largest sub-index which is supported.
Value = 1.
Sub-index1:
By read access the device provides information about its saving possibility.