Configuration using online commands
#
Technical description LSIS 22x
Leuze electronic
8
Configuration using online commands
Configuration can be performed via the RS 232 interface or via the USB interface with COM
port emulation with online commands.
Examples for online commands
Example 1
:
To, e.g., configure a <STX> as prefix, the following command string must be sent:
<SYN>M<CR>PREBK29902.
The response from the LSIS 22x is:
PREBK29902<ACK>.
If an
<ENQ>
is sent as response, the command syntax was incorrect.
If an
<NAK>
is sent, the command could not be executed because the permissible value/
range was exceeded.
Notice!
If no response is received to the sent command, the interface is probably not correctly set.
Example 2
:
To deactivate Code 128 as a readable code, the following command string must be sent:
<SYN>M<CR>128ENA0.
The response from the LSIS 22x is:
128ENA0<ACK>.
Notice!
The commands correspond to the content of the configuration codes that are printed in this
technical description. For further information on the topic of online commands, please con-
tact Leuze electronic.
Содержание LSIS 222
Страница 1: ...LSIS 222 LSIS 223 Code reader en 01 2012 07 50119062 T E C H N I C A L D E S C R I P T I O N ...
Страница 92: ...Appendix 90 Technical description LSIS 22x Leuze electronic 13 3 3 Other sample codes Figure 13 3 Sample codes ...
Страница 93: ...Appendix Leuze electronic Technical description LSIS 22x 91 TNT 35 7 24V Figure 13 4 Sample codes ...