Configuration using configuration codes
Leuze electronic
Technical description LSIS 22x
35
TNT
35/7-2
4
V
7.2.1
Manual/serial trigger mode
By reading in one of the following configuration codes, the
manual/serial trigger mode
is
set to either the
normal
or
enhanced
variant.
Figure 7.6:
Configuration codes for setting the manual/serial trigger mode
Read time-out for serial trigger
If the reading gate is to be closed after sending the
<SYN>T<CR> read start command
if
no code was read after a defined time, you can set a
read time-out
time. Values can be
set in the range
0 … 300,000ms
.
To do this, first read in the following configuration code and then, digit by digit, the
programming codes
(see "Programming codes for the configuration" on page 92) for the
numerical value of the read time-out time in milliseconds. Conclude parameter entry by
reading in the
Save
programming code.
Figure 7.7:
Configuration code for setting the read time-out time
Shown below is an example illustrating the principle for entering a parameter value.
Manual/serial trigger mode - normal
Manual/serial trigger mode - enhanced
Read time-out
Содержание LSIS 222