Electrical connection
Leuze electronic
Technical description LSIS 22x
23
TNT
35/7-2
4
V
5.2
Electrical connection of the LSIS 22x M5M-R1
The LSIS 22x is equipped with an A-coded M12 connector.
• The
voltage supply
(10 … 30VDC) is connected at
pin 1
and
pin 3
(
VB, GND
).
• The
switching input
is connected at
pin 2
(
SWI
).
• The
switching output
is connected at
pin 4
(
SWO
).
• The
RS 232 interface
is the host interface of the LSIS 22
2
M5M-R1.
It is connected at
pin 6
and
pin 7
(
TXD - data, RXD - data
).
• The
USB interface
is the host interface of the LSIS 22
3
M5M-R1.
It is connected at
pin 6
and
pin 7
(
D+ - data, D– - data
).
Figure 5.2:
Connections of the LSIS 22x
Described in detail in the following are the individual connections.
Attention!
Ensure that the functional earth (FE) is connected correctly. Unimpaired operation is only
guaranteed when the functional earth is connected properly.
Preferably, use the ready-made connection cables from Leuze electronic (see chapter 10.3
on page 78).
Supply voltage
Attention!
For UL applications, use is only permitted in class 2 circuits in accordance with the NEC
(National Electric Code).
The code readers of the LSIS 22x … series are designed in accordance with safety class III
for supply by PELV (protective extra-low voltage).
PIN
Signal
3
LSIS 22
3
LSIS 222
GNDIN
USB
RS232
1
Vin 10 … 30 V DC
VB 4.75 … 5.25 V DC
2
SWI
SWI
GND
4
SWO
SWO
5
not connected
not connected
6
RXD - Data
D+ - Data
7
TXD - Data
D- - Data
8
FE - Shield
FE - Shield
SH
FE - Shield
FE - Shield
M12, 8-pole
male, A-cod.
M12 plug
8-pin
(A-coded)