Configuration using configuration codes
Leuze electronic
Technical description LSIS 22x
37
TNT
35/7-2
4
V
7.2.2
Presentation mode
By reading in the following configuration code,
presentation mode
is set.
Figure 7.9:
Configuration code for setting the presentation mode
Notice!
For further optional settings on this parameter, please contact Leuze electronic.
Attention!
If a trigger occurs by means of a button or trigger input while the LSIS 22x is in
presentation mode, the LSIS 22x switches to manual/serial trigger mode!
Each time the trigger button is pressed or trigger input is activated, the LSIS 22x is again
activated as long as the trigger button is pressed or a high-signal is applied at the trigger
input.
If no trigger is initiated via the button or the switching input for the duration of the
hands
free time-out
time (factory setting: 5s), the LSIS 22x returns to presentation mode.
In manual/serial trigger mode, the
hands free time-out
time is not active.
Configuring the hands free time-out time
First read in the following configuration code and then, digit by digit, the
programming
codes
(see "Programming codes for the configuration" on page 92) for the numerical value
of the hands free time-out time in milliseconds. Conclude parameter entry by reading in the
Save
programming code.
Values can be set in the range
0 … 300,000ms
(factory setting: 5000ms) .
Figure 7.10: Configuration code for setting the hands free time-out time
Presentation mode
Hands free time-out