Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Manufacturer name
16
0
string
32 bytes
RO
Leuze electronic GmbH + Co. KG
Manufacturer text
17
0
string
64 bytes
RO
Leuze electronic - the sensor people
Product name
18
0
string
64 bytes
RO
Receiver type designation
Product ID
19
0
string
20 bytes
RO
Order number of the receiver (8-digit)
Product text
20
0
string
64 bytes
RO
“Measuring light curtain CML 720i”
Serial number
Receiver
21
0
string
16 bytes
RO
Serial number of the receiver for unique product
identification
Hardware version
22
0
string
20 bytes
RO
Firmware version
23
0
string
20 bytes
RO
User-specific name
24
0
string
32 bytes
RW
***
Device designation defined by the user
Device status
36
0
unsigned 8
R
0 … 4
Value: 0 device is OK
Value: 1 maintenance required
Value: 2 outside of specifications
Value: 3 function test
Value: 4 error
Receiver part no.
64
0
string
20 bytes
RO
Order number of the receiver (8-digit)
Transmitter product
designation
65
0
string
64 bytes
RO
Type designation
Transmitter part no.
66
0
string
20 bytes
RO
Order number of the transmitter (8-digit)
Transmitter serial
number
67
0
string
16 bytes
RO
Transmitter serial number for unique product iden
-
tification
Device characteristics
68
0
record 80 bit,
isolated
access to
sub-index not
possible
RO
The device characteristics specify the beam spac
-
ing, the number of physical/logical individual
beams, the number of cascades (16 individual
beams) in the device and the cycle time.
Beam spacing
68
1
(bit
offset
= 64)
unsigned 16
RO
5, 10, 20, 40
5
Distance between two adjacent optical individual
beams.
Number of physical indi
-
vidual beams
68
2
(bit
offset
= 48)
unsigned 16
RO
16
Number of configured
logical individual beams
68
3
(bit
offset
= 32)
unsigned 16
RO
16
The number of logical individual beams is depen
-
dent on the selected operating mode.
The evaluation functions of the CML 700i are cal
-
culated on the basis of the logical individual
beams.
Segment number of a
beam-stream with 16
beams
68
4
(bit
offset
= 16)
unsigned 16
RO
1
The CML 700i has a modular structure. 16 or 32
individual beams are always grouped into a cas
-
cade.
Device cycle time
68
5
(bit
offset
= 0)
unsigned 16
RO
1000
The device cycle time defines the duration of a
measurement cycle of the CML 700i.