Starting up the device - Basic configuration
Leuze electronic
CML 720i Ex
64
Example: with a filter depth of “5”, five measurement cycles must be consistent before an evaluation is
performed. For further information, see also the description of interference suppression (see
The structure of the configuration in the receiver control panel menu is as follows:
Select Main Settings > Operational Settings > Filter Depth.
8.5.4 Defining the display properties
With these configurations for the display, the brightness and a time unit for darkening the display are
defined.
Visibility:
• Off: no display; the display remains dark until a button is pressed.
• Dark: text is only slightly visible.
• Normal: text is visible with good contrast.
• Bright: text appears very bright.
• Dynamic: The display darkens gradually over the number of seconds configured under Time Unit (s).
During this time span, the display passes through all levels, from bright to off.
The structure of these configurations in the receiver control panel menu is as follows:
For all digital process interfaces, the configuration can also be performed via the respective field
-
bus interface (see chapter 9 et seq.) or via the
Sensor Studio
configuration software (see
When configuring the filter depth, you can enter values of up to 255. Values above 255 (to 299)
are not accepted and must be entered again.
Level 0
Level 1
Level 2
Description
Main Settings
Commands
Teach
Reset
Factory settings
Operational setting
Filter Depth
(enter value)
min = 1
max = 255
After approx. 5 minutes without button actuation, configuration mode is exited and the display
changes to the previous mode.
When configuring the Visibility in the dark, normal and bright modes, the display is completely
inverted after approx. 15 minutes to prevent the LEDs from burning in.
When configuring the Time Unit (s), you can enter values of up to 240 seconds. Values above
240 (to 299) are not accepted and must be entered again.
Level 0
Level 1
Level 2
Description
Display
Language
English
German
French
Italian
Spanish
Operating
mode
Process mode
Alignment
Visibility
Off
Dark
Normal
Bright
Dynamic
Time Unit (s)
(enter value)
min = 1