Example configurations
Leuze electronic
CML 720i Ex
105
Configuring light curtain 3:
Configure the trigger settings (triggered, slave, delay time).
Configure the digital IOs (pin 5) settings.
11.6.2 Configuration of a cascading arrangement via IO-Link interface
CML700i frame arrangement for cascading with IO-Link interface wiring
1
Receiver
2
Transmitter
3
Interconnection cable 5 m (see table 17.3)
4
Connection cable 5 m (see table 17.4)
5
Interconnection cable 2 m (see table 17.3)
Pin 5 - Input/output selection
1: Input
Pin 5 - Switching behavior
0: Light switching
Pin 5 - Output function
1: Trigger input
Cascading configuration
Cascading
1: Active
Note: With cascading operation, the master must also be set to 1 (active)!
Function type
0: Slave (expects trigger signal)
Trigger delay time → Scan [us]
Enter cycle time of light curtain 1 and light curtain 2 (= sum of cycle times of light curtains LC1+LC2)
Digital IO1 (pin 5) settings
Pin 5 - Input/output selection
1: Input
Pin 5 - Switching behavior
0: Light switching
Pin 5 - Output function
1: Trigger input
2
2
1
5
1
2
3
4
1
3
4