Important Parameters
Leuze
electronic
58
BCL 21/22
Leuze electronic
Deactivation
10.4
Communication
Figure 10.5: Standard setting of the communication menu
Select the desired baud rate, the stop bits, the data bits and the parity here. In addition,
several different handshake modes and protocols can be set here.
Sensor 1 function
see menu "switching input"
Reading security
reached (equal
scans)
If this item is activated, the read result is output immediately after the
bar code is decoded.
If the item is deactivated, the read result is sent only after the trigger
signal is returned (=end of reading gate).
Command
character
The standard online character for the trigger end is the ´-´ character.
This character can be changed only via the tree structure.
Time
For test purposes.
If the scanner is activated, the reading gate is automatically closed by
the scanner after this preset time has elapsed.
Scans without info
Following a successful read, the scanner waits for this number of
scans (sequential scans with no read result) before it automatically
deactivates itself.