Leuze
electronic
Online commands
Leuze electronic
BCL 21/22
69
TNT 35/7-24V
Teach-In
Notice!
With this function, only code types are recognised that are identified using the autoConfig
function or which were set in the set-up.
!
After each reading via an ’RTx’ command, explicitly switch off the function again since
failure to do so will interfere with other commands as well as prevent execution of a new
’RTx’ command.
Command
’RT’
Description
This command enables a reference code to be defined quickly by read-
ing an example label.
Parameter
’RTy’
y
: Function
’1’
defines reference code 1
’2’
defines reference code 2 …
’9’
defines reference code 9
’+’
activates the definition of reference code 1 up to the value of Param-
eter no_of_labels
’-’
Exit the Teach-In process
Acknowledge-
ment
The BCL first responds with the command
’RS’
and corresponding sta-
tus (see command RS). After a barcode has been read, it sends the
result in the following format:
’RCyvxxzzzzz’
y
,
v, x
and
z
are placeholders (variables) for the actual input.
y
: def. reference code No.
’1’
(Code 1) …
’9’
(Code 9)
v
:
Storage location for reference code
’0’
RAM+EEPROM,
’3’
RAM only
xx
def. Code type (see command ’CA’)
z
def. Code information (1 … 63 characters)
Содержание BCL 21
Страница 85: ......