Leuze
electronic
Online commands
Leuze electronic
BCL 21/22
71
TNT 35/7-24V
11.1.2
’Online’ Commands for System Control
System Standby
System boot-up
Activate sensor input 1
Deactivate sensor input 1
Activate sensor input 2
Command
’SS’
Description
System Standby: puts the bar code reader in standby mode. The scanner
cannot be triggered, and the polygon wheel motor is stopped.
Parameter
no
Acknowledge-
ment
no
Command
’SA’
Description
System boot-up: reactivates the bar code reader from standby mode back
to operating mode. The polygon wheel motor is started, the scanner works
as usual.
Parameter
no
Acknowledge-
ment
’S’
(start signal)
Command
’+’
Description
The command activates decoding.
Parameter
no
Acknowledge-
ment
no
Command
’-’
Description
The command deactivates decoding.
Parameter
no
Acknowledge-
ment
no
Command
’,’
Description
The command activates the definition of reference code 1.
Parameter
no
Acknowledge-
ment
no
Содержание BCL 21