![Leuze electronic BCL 21 Скачать руководство пользователя страница 65](http://html.mh-extra.com/html/leuze-electronic/bcl-21/bcl-21_technical-description_1883905065.webp)
Leuze
electronic
Online commands
Leuze electronic
BCL 21/22
63
TNT 35/7-24V
11
Online commands
11.1
Overview of Commands and Parameters
Online commands can be used to send commands directly to the device for control and
configuration.
For this the BCL 21/22 with MA 2/MA 4… must be connected to a host or service computer
via the serial interface. The commands described can be sent either via the host or the
service interface.
For information on the transmission protocol, please see chapter 7.3.1.
Online commands
With the commands, you can
• control/decode.
• read/write/copy parameters.
• carry out an automatic configuration.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialise the device.
Syntax
"Online" commands consist of one or two ASCII characters followed by command parame-
ters.
No separation characters may be entered between the command and the command param-
eter(s). Both small and capitalised letters can be used.
Example:
Command
’CA’
:
autoConfig function
Parameter
’+’
:
Activation
Transmitted is:
’CA+’
Notation
Commands, command parameters and returned data are enclosed between single quota-
tion marks
’ ’
in the text of this manual.
Most online commands are acknowledged by the BCL 21/22 and any requested data
returned. For commands that are not acknowledged, command execution can be observed
or monitored directly on the device.