![Leroy-Somer VARMECA 20 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/leroy-somer/varmeca-20/varmeca-20_parameter-setting-manual_1883154007.webp)
49
PARAMETER SETTING MANUAL
VARMECA 20
Variable speed motors and geared motors
COMMISSIONING THE CDC-VMA 20 CONSOLE
LEROY-SOMER
3532 - 05.2004 / f
en
2 - COMMISSIONING THE
CDC-VMA 20 CONSOLE
2.1 - Installation
2.1.1 - Checks on receipt
When you receive your CDC-VMA 20 console, make sure
that it has not been damaged during transport. Should
damage have occurred, please report it to those responsible
for its transport.
2.1.2 - Connection
- Open the front cover of the VARMECA 20.
- Connect the 4-pin socket at the end of the cable to the
connector located on the VARMECA 20 connection card.
- The cable SUB-D socket is then connected to the console
SUB-D socket.
2.2 - Presentation of the CDC-VMA 20 keyboard
CDC
-VMA 20
MEM.
P01
FMIN.
P02
REF 0V 4MA
P03
F MAX.
P04 REF 10V 20MA
P05
ACCEL.
P06
DECEL.
P07
STOP MODE
P10
U / F
P11
BOOST
P23
F MOT
.
P24
I MOT
.
FREQUENCE MIN.
HZ
ETALONNAGE CONSIGNE MIN. HZ
FREQUENCE MAX.
HZ
ETALONNAGE CONSIGNE MAX. HZ
HZ
RAMPE ACCEL.
RAMPE DECEL.
S
MODE D'ARRET
0 = ROUE LIBRE
1 = RAMPE
L
OI U / F
0 = FIXE
1 = DYNAMIQUE
BOOST
%
LECTURE FREQUENCE MOTEUR
LECTURE COURANT MOTEUR A/10
MIN. FREQUENCY
HZ
MIN. REF. SCALING
HZ
MAX. FREQUENCY
HZ
MAX. REF. SCALING
HZ
ACCEL. RAMP
DECEL. RAMP
S
S
S
STOPPING MODE
0 = FREE WHEEL
1 = RAMP
U / F RATIO
0 = FIXED
1 = DYNAMIC
BOOST
%
MOTOR FREQUENCY STATUS HZ
MOTOR CURRENT STATUS A/10
MIN. FREQUENZ
HZ
ABGLEICH SOLLWERT MIN.
HZ
MAX. FREQUENZ
HZ
ABGLEICH SOLLWERT MAX.
HZ
HOCHLAUF RAMPE
AUSLAUF RAMPE
S
S
HALTE MODUS
0 = FREILAUF
1 = RAMPE
U / F KENNLINIE
0 = FEST
1 = DYNAMISCH
BOOST
%
MOTOR FREQUENZ ANZEIGE HZ
MOTOR STROM ANZEIGE
A/10
Summary table of
main parameters
Keys for scrolling through
the various parameters,
and modifying the content
Key for storing settings