![Leroy-Somer VARMECA 20 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/leroy-somer/varmeca-20/varmeca-20_parameter-setting-manual_1883154038.webp)
80
PARAMETER SETTING MANUAL
VARMECA 20
Variable speed motors and geared motors
WIRING DIAGRAMS
LEROY-SOMER
3532 - 05.2004 / f
4.10 - Configuration 7: "Faster/slower command" (VMA B20 only)
Marking
Functions - Characteristics
Connection of protected mains supply phases
L1, L2 or 200V to 240V ± 10% 50-60Hz in single-phase
L1, L2, L3 220V to 480V ± 10%, 50-60Hz in three-phase
PE
Earth connection
R1, R2
Connection of the braking resistor (optional)
VMA21 - min. resistance value = 200 Ohms
VMA22 - min. resistance value = 200 Ohms
1
Locking logic input
Terminals 1 and 3 not connected: drive disabled
Terminals 1 and 3 connected: drive enabled
2
Logic input: Enabling of reduced speed
S4 Open: Operation at reduced speed (VP1-1)
S4 Closed: Operation at max. speed
3
24VDC, 30mA
Common at terminal 10
4
10V, 10mA
5
0 V
6
Reference input 0 to +10V or 4-20mA
0-10V: input impedance = 100kOhms
4-20mA: input impedance = 0.5kOhms
7
Run Reverse/Maintain speed logic input
8
Run Forward/Maintain speed logic input
9
Acceleration up to F max. logic input
10
24VDC, 30mA
Common at terminal 3
11, 12
Fault relay - volt-free contact 250V 1A
Contact open: switched off or faulty
Contact closed: running
1
2
3
4
L1
L2
L3
R1
R2
PE
5
6
7
8
9
10
+24V
11
12
QS : Fused isolator
AU : Emergency stop
SB1 : Off button
SB2 : On button
0V
+10V
+24V
Run reverse
Maintain
speed
Run forward
Acceleration
Fault relay
VARMECA 20
QS
KM1
SB2
KM1
SB1
AU
Remote control
power supply
Mains
power supply
KM1
Braking
resistor
(Optional)
S1
S2
S3
S4
Selection of
reduced speed
Associated parameter setting
CDC-VMA 20
PEGASE VMA 20
P60 = ON
Dynamic control = YES
P14 = Config. 7
Terminal block configuration = Config. 7
P15 = VP1-1
VP1 option 1-4
P61 = dep. on application
Brake release F
P62 = dep. on application
Brake engage F
P63 = dep. on application
T1 release
P64 = dep. on application
T2 magnetisation
P65 = dep. on application
DC injection time delay
P66 = dep. on application
T4 brake engage
P67 = dep. on application
DC injection level
P68 = dep. on application
I threshold before brake release