78
PARAMETER SETTING MANUAL
VARMECA 20
Variable speed motors and geared motors
WIRING DIAGRAMS
LEROY-SOMER
3532 - 05.2004 / f
4.9 - Configuration 6: Jog operation command
Marking
Functions - Characteristics
Connection of protected mains supply phases
L1, L2 or 200V to 240V ± 10% 50-60Hz in single-phase
L1, L2, L3 220V to 480V ± 10%, 50-60Hz in three-phase
PE
Earth connection
R1, R2
Connection of the braking resistor (optional)
VMA21 - min. resistance value = 200 Ohms
VMA22 - min. resistance value = 200 Ohms
1
Locking logic input
Terminals 1 and 3 not connected: drive disabled
Terminals 1 and 3 connected: drive enabled
2
Speed analogue output 0 to +10V, 3mA or analogue
input 0-10V - 4-20mA
0V = zero speed
10V = maximum speed
3
24VDC, 30mA
Common at terminal 10
4
10V, 10mA
5
0 V
6
Reference input 0 to +10V or 4-20mA
0-10V: input impedance = 100kOhms
4-20mA: input impedance = 0.5kOhms
7
Run Reverse logic input
8
Run Forward logic input
9
Stop and run authorisation logic input
10
24VDC, 30mA
Common at terminal 3
11, 12
Fault relay - volt-free contact 250V 1A
Contact open: switched off or faulty
Contact closed: running
1
2
3
4
L1
L2
L3
R1
R2
PE
5
6
7
8
9
10
+24V
11
12
QS : Fused isolator
AU : Emergency stop
SB1 : Off button
SB2 : On button
0V
+10V
+24V
Reverse
Forward
Stop
Fault relay
VARMECA 20
QS
KM1
SB2
KM1
SB1
AU
Remote control
power supply
Mains
power supply
KM1
Braking
resistor
(Optional)
SA5
SA4
SA3
Control
potentiometer
Associated parameter setting
CDC-VMA 20
PEGASE VMA 20
P14 = Config. 6
Terminal block configuration = Config. 6
Reference
Mini Dip K1
0 -10V
ON
4 -20mA
OFF