8-2
8.2 Setting the 12-Lead ECG Acquisition
You can perform the following operations on the 12-lead screen:
[Start / Stop]: press this button to start / stop ECG acquisition.
[Freeze]: press this button to freeze the currently displayed
waveforms on the screen and enter the freeze screen.
[Real-time]: set the sampling mode, real-time sampling and
pre-sampling can be selected. The default is real-time sampling.
[10mm/mV]: set the gain of the waveforms.
Options: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV.
The default is 10mm/mV.
[25mm/s]: set the speed of the waveforms.
Options: 25mm/s, 50mm/s. The default is 25mm/s.
[6×2+1R]: set the 12-lead waveform layout.
Options: 6×2+1R, 3×4+1R. The default is 6×2+1R.
[10s]: set the acquisition time.
Options: 10s, 20s, 30s, 60s. The default is 10s.
[Exit]: press this button to exit the 12-lead screen and return to
the main screen.
If you press this button to exit during the acquisition process, the
system will pop up the exit confirmation prompt.
8.3 Connecting to the AI-ECG Server
Before initiating 12-lead ECG acquisition, please set up the network
and connect the monitor to the server of AI-ECG Platform. For the
specific setting method, please refer to
8.4 Initiating 12-Lead ECG Acquisition
After connecting the AI-ECG server, before 12-lead ECG acquisition,
please select and install electrodes according to the introduction of
, check that all electrodes and cables
have been properly connected, the patient information is set
correctly, and always keep the patient quiet.
To initiate 12-lead ECG acquisition, press the [Start] button in the
lower right corner of the [ECG 12-Lead] screen.
Real-time sampling: acquire the ECG data of the set acquisition
time after pressing the [Start] button. During the acquisition
process, the remaining acquisition time is displayed. At the
completion of acquisition, the system enters the preview screen.
Содержание AIView 12V
Страница 1: ...AIView Series Patient Monitor Operator s Manual...
Страница 2: ......
Страница 6: ...IV This page intentionally left blank...
Страница 24: ...1 7 This page intentionally left blank...
Страница 26: ...2 2...
Страница 31: ...2 7 2 6 2 Rear View 1 2 3 4 1 Handle 2 Device label 3 Equipotential grounding terminal 4 AC power connector...
Страница 34: ...2 10 2 6 5 Bottom View 1 2 2 2 2 1 Battery compartment 2 Anti slip foot pad...
Страница 35: ...2 11 This page intentionally left blank...
Страница 44: ...3 9 1 2 3 4 5 8 9 7 6...
Страница 55: ...3 20 This page intentionally left blank...
Страница 71: ...5 11 This page intentionally left blank...
Страница 78: ...6 7 This page intentionally left blank...
Страница 106: ...8 5 This page intentionally left blank...
Страница 112: ...9 6 This page intentionally left blank...
Страница 119: ...10 7 This page intentionally left blank...
Страница 129: ...11 10 2 Set PR Source select an appropriate PR source from the drop down list...
Страница 165: ...15 12 Other sources of interference if any...
Страница 166: ...15 13 This page intentionally left blank...
Страница 181: ...17 8 Select Range to view the normal range of each parameter Select Unit to view the unit of each parameter...
Страница 185: ...17 12 Select Range to view the normal range of each parameter Select Unit to view the unit of each parameter...
Страница 194: ...17 21 This page intentionally left blank...
Страница 204: ...19 5 This page intentionally left blank...
Страница 210: ...20 6 This page intentionally left blank...
Страница 229: ...23 10 This page intentionally left blank...
Страница 248: ...25 8 This page intentionally left blank...
Страница 251: ...A 3 Shutdown Delay At least 5 minutes since the first low battery alarm...
Страница 283: ...D 2 This page intentionally left blank...
Страница 289: ...E 6 less than 3V m...