background image

www.LeonAudio.com.au

C

B

5

Configuration

Commands

PCinterface

Value

Description

Description

Header Byte

R

B

H

P

T

Monitoring Reply Mode

Baud Rate

Heart Beat Signal

Reply Pacing.  Pause between 

each 5 byte reply

Terminator chx for replies

0
1

0
1
2
3
4
5

0
1

0
1
2
3
4
5
6

0
1
2
3
4
5

Simple GUI Reply
Channel & Function Reply  with

all ASCII characters.

2400 baud
9600 baud
19200 baud
38400 baud
57600 baud
115200 baud

Off
On

0uS
100uS
300uS
1mS
3mS
10mS
30mS

none
}

7Dh

|

7Ch

space

20h

line feed

0Ah

~

7Eh

(Left curly bracket)

Function

C

R

R

(

)

fixed value

PCinterface

(

)

fixed value

{

Table of PCinterface Configuration Commands

Summary of Configuration Commands

78.

R

5

C

5

{

B

R

{

5

C

R

{

B

C

R

{

5

C B

B

Содержание PCinterface QL-PCi Mk4

Страница 1: ...k4 16 channel Cue Light control from your Touch Screen or Show Control PC Control up to 6 Cue Light Master Stations Control 240 Outstations across 96 channels Simple 5 byte ASCII commands Return Statu...

Страница 2: ...PCi will now be sending the Heart Beat signal to the Show Control computer This is a 5 byte ASCII string RRH1 Basic Control Commands are 5 ASCII bytes RS232 port on the 2 3 PCinterface QL PCi Mk4 Show...

Страница 3: ...unctions Table of Sensor Outstation Configuration Commands Unsafe Lamp Safe when open closed End Of Line Resistors All Lamps on Outstation 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 4...

Страница 4: ...rface to PC serial link PCinterface Loop back Test A 10 second test What if it doesn t work Connections Summary of Commands Programming Simple GUI Commands Table of button numbers Table of Cue Sheet C...

Страница 5: ...button can be pressed or released Cue Light Outstations and Masters A single PCinterface can control from 1 to 6 Master Stations Each 16 channel Master can control up to 40 Outstations giving a maximu...

Страница 6: ...GUI command format A simple command interface for touch screens The touchscreen sends a command to the PCinterface when any touchscreen button is pressed or released This toggles the function of that...

Страница 7: ...hen the Pressed command is sent it must always be followed by a Released command either immediately or after other commands that are executed while that key is still pressed Examples Master 4 N Simple...

Страница 8: ...ll A B GO Group Fault Standby Call A B GO Group Fault Standby Call A B www LeonAudio com au Cue Light Master QLM16 Mk4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 50 51 52 53 54 55 56 57 58 59 60 61 62 63...

Страница 9: ...Call Call A A A A A A A A A A A A A A A A B B B B B B B B B B B B B B B B www LeonAudio com au Cue Light Master QLM16 Mk4 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Standby Standby GO GO 50 51 52 53 54 55...

Страница 10: ...59 60 61 62 63 64 65 Go Buttons 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 Other buttons Red Beep Button 82 White Dimmer Button 83 Group Master Buttons Group A Standby 84 Group B Standby 85 Group...

Страница 11: ...when starts Request the Lamp Status for all channels 1SQ1 to update the display on the touch screen Touch Screen Controller is running when Cue Lights start There is nothing special to do in this case...

Страница 12: ...1 Master 2 Master 3 Master 4 Master 5 Master 6 For use with a show control system with a pre loaded cue list The control system sends a command s to the PCinterface when the Next cue button is presse...

Страница 13: ...as a decimal number 00d to 16d or as an ASCII character 1 5 G 1 Channel Number Cue Sheet Commands For ASCII Channel Numbers These options are enclosed in round brackets No spaces are allowed Channel...

Страница 14: ...1 Ch 12 S by Cue Clear Either a letter or a number can be used for the ASCII Value Use which ever you prefer Letters are not case sensitive S by Cue Same as Go Clear and S by Clear but in a single com...

Страница 15: ...numbers can be used for the ASCII Value of the last 7values Use which ever you prefer Values of A G can be replaced by a double digit number inside curved brackets 15 Value Group Button A B C D E F G...

Страница 16: ...s no Normal mode Outstation connected but has one or more Eavesdrop mode Outstations connected To turn off steady Fault Lamps connect one Outstation set to Normal mode to the channel in question F S 1...

Страница 17: ...on 5 mS click 60mS 120 mS 180 mS 240 mS 300 mS 360 mS 420 mS 480 mS 540 mS 600 mS 660 mS 720 mS 780 mS 840 mS 900 mS 960 mS 0 1 2 3 4 5 6 7 8 9 A or 10 B or 11 C or 12 D or 13 E or 14 F or 15 G or 16...

Страница 18: ...el Function Reply 1 5 G 1 Channel Function Reply The Function varies depending on the letter in the Channel Number position Refer to the table on page 24 for details Channel Number 1 9 A B C D E F G S...

Страница 19: ...scellaneous Command Request Lamp Status Fixed value no choices Request Lamp Status command 1 S Q 1 Value Command 0 1 Simple GUI Reply Channel Function Reply This command configures the PCinterface and...

Страница 20: ...1 R R H 1 20h 20h R R H 1 R R H 1 10h 10h R R H 1 R R H 1 R R H 1 R R H 1 Value 0 1 2 3 4 5 none space line feed Termination Character Termination Character 0 T C R Configuration Header PCinterface co...

Страница 21: ...eader PCinterface configuration PCinterface configuration Reply Pacing Reply Pacing Value 0 6 Add a pause between each 5 byte reply if the receiving system is unable to process the incoming data quick...

Страница 22: ...1 32 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 82 83 82 83 107 84 85 108 112 116 109 113 117 1...

Страница 23: ...e 112 113 114 115 Safe 116 117 118 119 Other Lamps Group A Master Lamps 82 S by Go buttons light as a pair Group B Master Lamps 83 S by Go buttons light as a pair Short Lamp 84 Aux lamp 85 not fitted...

Страница 24: ...Aux Lamp not fitted Left square bracket Function 1 2 3 4 5 6 1 1 5 G Off On Flash Off On Off On Off On Flash Off On Flash Dimmed Off On Flash Dimmed Off On Flash Off On Flash Off On Off Dimmed Off Di...

Страница 25: ...aster s on line status 0 1 Just gone off line Just come on line Master 1 has just come on line Master 2 has just gone off line Examples 1 0 S 1 2 0 S 0 The Heart Beat signal is generated by the PCinte...

Страница 26: ...eader Header character to mark the start of a command Configuration Command Format Each configuration option is discussed in detail under Master Station s Configuration Editor in the PDF file 16 Chann...

Страница 27: ...nd 11 Channels 1 2 3 9 14 15 16 The basic channel address is a single byte It can be entered as a decimal number 00d to 16d or as an ASCII character 1 5 A 1 Channel Number For ASCII Channel Numbers Th...

Страница 28: ...mp flashes ACK button back light Beeper enable Beep on Go Change colour on ACK Dimmer S by colour Factory Default Yellow Flashes Flashes Latches No Steady Times out Flashes Latches Interlocked Enabled...

Страница 29: ...mentary Independent Call lamp off Steady Off Disabled Beeps 4 choices Change colour 5 100 in 5 steps User Selectable Function Function A B C D E F G H J K M N P Q R S T Summary of Cue Light Outstation...

Страница 30: ...or E 0 or S 1 or F 0 or F 1 or N 0 1 2 3 0 or N 1 or C 1 2 3 4 5 Red Yellow Steady Flash Momentary Latches No DIM on ACK DIM on ACK Steady Flicker No time out Times out after delay Steady Flashes aft...

Страница 31: ...her a letter or a number can be used for the ASCII Value Use which ever you prefer Letters are not case sensitive Outstation S by colour S by Flash on Master S by Flash on Outstation S by latches S by...

Страница 32: ...sed for the ASCII Value Use which ever you prefer Letters are not case sensitive Outstation S by Flash on Master Beeper enable S by colour S by Flash on Outstation S by latches S by Dims on ACK Outsta...

Страница 33: ...ASCII Value Use which ever you prefer Letters are not case sensitive Outstation S by Flash on Master S by Flash on Outstation S by latches Go times out Go flashes Go latches Go S by interlocked Call...

Страница 34: ...enabled Call lamp flashes ACK button back light Beep on Go Change colour on ACK Dimmer S by colour Go times out Go flashes Beeper enable Function A B C D E F J K M N P Q R S T G H Summary of Cue Light...

Страница 35: ...latches Go S by interlocked Function A B C D E F G H M N P Q R S T J K Summary of Cue Light Outstation Functions 35 Factory default Master 1 Ch5 Go momentary action Master 1 Ch5 Go latching action Ex...

Страница 36: ...Q R S T M N Summary of Cue Light Outstation Functions 36 Factory default Master 1 Ch5 Call lamp disabled Master 1 Ch5 call lamp enabled Examples 1 5 1 5 Master 1 Ch5 Call lamp steady Master 1 Ch5 Call...

Страница 37: ...aster number 0 6 Channel number 0 16 Beeper enable Value Factory default Master 1 Ch5 ACK button back light off Master 1 Ch5 ACK button back light on Examples 1 5 1 5 Master 1 Ch5 Beeper off disabled...

Страница 38: ...5 Beep on Go 50mS Examples 1 5 1 5 R 0 2 R Value 0 1 2 3 Off 1mS Note 1 50mS 200mS Beep on Go duration Function is Upper Case Function is Upper Case Cue Light Outstation Functions Configuration Comman...

Страница 39: ...hes Go latches Go S by interlocked Call lamp enabled Call lamp flashes ACK button back light Beeper enable Beep on Go Change colour on ACK S by colour Dimmer Function A B C D E F G H J K M N P Q R S T...

Страница 40: ...Enabled Flashes Enabled 5 modes Steady Steady Momentary Stays on Steady Momentary Independent Call lamp off Steady Off User Selectable Function Function a b c d e f g h j k m Summary of Relay Outstati...

Страница 41: ...e Light Mode Steady Flashes Steady Flashes Momentary Latches No time out Times out after delay Steady Flashes after 3 secs Momentary Latches Independant Interlocked Disabled Enabled Steady Flashes Dis...

Страница 42: ...s on Outstation Function a b c d e f g h j k m Summary of Relay Outstation Functions Standby Lamp Flash on Master 1 Configuration Header Master number 0 6 Channel number 0 16 Standby Lamp Flash on Mas...

Страница 43: ...flashes on Outstation Examples 1 5 1 5 Either a letter or a number can be used for the ASCII Value Use which ever you prefer Letters are not case sensitive Function is Lower Case S by latches 1 Confi...

Страница 44: ...number 0 6 Channel number 0 16 Go Flashes after 3 seconds Value Either a letter or a number can be used for the ASCII Value Use which ever you prefer Letters are not case sensitive Either a letter or...

Страница 45: ...annel number 0 16 Go latches Value Go Standby interlocked 1 Configuration Header Master number 0 6 Channel number 0 16 Go Standby interlocked Value Master 1 Ch5 Go momentary action Master 1 Ch5 Go lat...

Страница 46: ...ber 0 6 Channel number 0 16 Call lamp flashes Value Factory default Master 1 Ch5 Call lamp disabled Master 1 Ch5 call lamp enabled Examples 1 5 1 5 Master 1 Ch5 Call lamp steady Master 1 Ch5 Call lamp...

Страница 47: ...on is Lower Case 1 Configuration Header Master number 0 6 Channel number 0 16 All Lamps on Outstation Value Factory default Master 1 Ch5 All Lamps on Outstation disabled Master 1 Ch5 All Lamps on Outs...

Страница 48: ...t Steady Open No EOL Enabled Flash Closed Two EOL Disabled User Selectable Function Function 1 2 3 4 Summary of Sensor Outstation Functions Sensor Outstation Functions Configuration Commands All comma...

Страница 49: ...EOL Disabled Enabled Left curly bracket Note 1 Function 0 Global 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 Global 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 A or 10 B or 11 C or 12 D or 13 E or 14 F or 15 G or 1...

Страница 50: ...Master number 0 6 Channel number 0 16 Safe when open closed Value Master 1 Ch5 Safe when open Master 1 Ch5 Safe when closed Examples 1 5 1 5 Either a letter or a number can be used for the ASCII Valu...

Страница 51: ...used for the ASCII Value Use which ever you prefer Letters are not case sensitive 3 0 2 3 1 Configuration Header Master number 0 6 Channel number 0 16 All Lamps on Outstation Value Master 1 Ch5 All La...

Страница 52: ...User file 2 read write 3 User file 3 read write 4 User file 4 read write 5 ShowTime file read write 6 Installer s Defaults read write 7 Factory Defaults with red Standby lamps read only 8 Factory Defa...

Страница 53: ...r 11 C or 12 D or 13 E or 14 F or 15 G or 16 0 1 Installer s Default file User file 1 User file 2 User file 3 User file 4 ShowTime file Factory default red S by Factory default yellow S by Installer s...

Страница 54: ...sending 1MA7 to the PCinterface As this command executes as soon as it is received an X for eXecute is not required NSOF Start of file Configuration file for Master number 1 File Factory Default Yell...

Страница 55: ...0 No colour change 1 Change colour Ch1 0000 0000 0000 0000 Ch16 11S0 12S0 13S0 14S0 15S0 16S0 17S0 18S0 19S0 1AS0 1BS0 1CS0 1DS0 1ES0 1FS0 1GS0 Dimmer 1 5 1 dimmest 5 brightest 100 Ch1 5555 5555 5555...

Страница 56: ...econds 1MEF Master Link the 4 Group Master buttons 1 Linked 0 Not linked 1 1MF1 Execute all the above commands when this file is sent to the PCinterface QL PCi X End of file NEOF Copy 1 of 8 files to...

Страница 57: ...to the ShowTime file Installer s Defaults User file 1 User file 2 User file 3 User file 4 ShowTime file Defaults red S by Defaults yellow S by 1 Configuration Header Master number 0 6 Master Config f...

Страница 58: ...10 B or 11 C or 12 D or 13 E or 14 F or 15 G or 16 1 to 9 seconds 10 seconds 11 seconds 12 seconds 13 seconds 14 seconds 15 seconds 16 seconds Go Cue Total Duration Master 1 Go Cue duration 6 seconds...

Страница 59: ...s execute as soon as they are received an X for eXecute is not required Note 59 PCinterface Functions Monitoring Reply Mode Baud Rate Heart Beat Signal Idle Character Reply Pacing Pause between each 5...

Страница 60: ...g Pause between each 5 byte reply Terminator chx for replies 0 1 0 1 2 3 4 5 0 1 0 1 2 3 4 5 6 0 1 2 3 4 5 Simple GUI Reply Channel Function Reply with all ASCII characters 2400 baud 9600 baud 19200 b...

Страница 61: ...ng Monitoring Reply Mode command Value Command 0 1 Simple GUI Reply Channel Function Reply R C R 0 R C R 1 Monitoring Reply Mode 0 Configuration Header PCinterface configuration PCinterface configurat...

Страница 62: ...ut 4 secs Release the Reset button as soon as the Tx and Rx lamps start to flash fast They only flash fast for 500mS so the window of opportunity is small If successful the Rx lamp will burn steady fo...

Страница 63: ...it It does not indicate that any Cue Light Outstations are connected The Heart Beat signal is reset to ON when ever the PCinterface is powered up Heart Beat signal The Heart Beat signal can be turned...

Страница 64: ...Pacing set to 30mS the same command takes 3 4 seconds to return the same data Reply Pacing 0 Configuration Header PCinterface configuration PCinterface configuration Reply Pacing Reply Pacing Value 0...

Страница 65: ...efault terminator as shipped is none R R H 1 R R H 1 R R H 1 R R H 1 R R H 1 R R H 1 20h 20h R R H 1 R R H 1 10h 10h R R H 1 R R H 1 Value 0 1 2 3 4 5 none space line feed Termination Character Termin...

Страница 66: ...Example R R 2 Testing PCinterface Loop back Test The PCinterface has a built in test mode All you need to run it is a loop back lead When powered up the PCinterface sends a heartbeat signal once per s...

Страница 67: ...ee the following Both Tx Rx lamps on the PCinterface will blink together at about once per second On the Master A single Group A lamp will light on a channel 1 6 that corresponds with the address that...

Страница 68: ...and setup it up for N 8 1 with hand shaking off Set the terminal program to 9600 baud If characters other than RRH1 are received try other baud rates or reset the PCinterface to 9600 baud See page 62...

Страница 69: ...receiver The PCinterface is wired as a DCE Null Modem Use a standard straight through serial modem cable for connection to the PC The female DB9 connector of the PCinterface unit receives data on pin...

Страница 70: ...he PC show controller You will need to add the wire links highlighted in red 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 Isolated Gnd 4 Tx 5 Tx 6 Isolated Gnd 7 Rx 8 Rx RJ45 RS485 connector wiring viewe...

Страница 71: ...67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 Other buttons Red Beep Button 82 White Dimmer Button 83 Group Master Buttons Group A Standby 84 Group B Standby 85 Group A Go 86 Group B Go 87 A specific b...

Страница 72: ...ration 5 mS click 60mS 120 mS 180 mS 240 mS 300 mS 360 mS 420 mS 480 mS 540 mS 600 mS 660 mS 720 mS 780 mS 840 mS 900 mS 960 mS 0 1 2 3 4 5 6 7 8 9 A or 10 B or 11 C or 12 D or 13 E or 14 F or 15 G or...

Страница 73: ...ight Beeper enable Beep on Go Change colour on ACK Dimmer S by colour Factory Default Yellow Flashes Flashes Latches No Steady Times out Flashes Latches Interlocked Enabled Flashes On Enabled Silent N...

Страница 74: ...or S 1 or F 0 or F 1 or N 0 1 2 3 0 or N 1 or C 1 2 3 4 5 Red Yellow Steady Flash Momentary Latches No DIM on ACK DIM on ACK Steady Flicker No time out Times out after delay Steady Flashes after 3 se...

Страница 75: ...tch A Latch B Mom Cue Light Mode Steady Flashes Steady Flashes Momentary Latches No time out Times out after delay Steady Flashes after 3 secs Momentary Latches Independent Interlocked Disabled Enable...

Страница 76: ...en Closed No EOL two EOL Disabled Enabled Left curly bracket Note 1 Function 0 Global 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 Global 1 2 3 4 5 6 0 1 2 3 4 5 6 7 8 9 A or 10 B or 11 C or 12 D or 13 E...

Страница 77: ...to 9 A or 10 B or 11 C or 12 D or 13 E or 14 F or 15 G or 16 0 1 Installer s Default file User file 1 User file 2 User file 3 User file 4 ShowTime file Factory default red S by Factory default yellow...

Страница 78: ...0 1 2 3 4 5 0 1 0 1 2 3 4 5 6 0 1 2 3 4 5 Simple GUI Reply Channel Function Reply with all ASCII characters 2400 baud 9600 baud 19200 baud 38400 baud 57600 baud 115200 baud Off On 0uS 100uS 300uS 1mS...

Страница 79: ...16 117 118 119 Other Lamps Group A Master Lamps 82 S by Go buttons light as a pair Group B Master Lamps 83 S by Go buttons light as a pair Short Lamp 84 Aux lamp 85 not fitted 92 1 N 1 A specific lamp...

Страница 80: ...A Master Group B Master Short Lamp Aux Lamp not fitted Left square bracket Function 1 2 3 4 5 6 1 Off On Flash Off On Off On Off On Flash Off On Flash Dimmed Off On Flash Dimmed Off On Flash Off On Fl...

Страница 81: ...6C l 013 00D CR 045 02D 077 04D M 109 06D m 014 00E SO 046 02E 078 04E N 110 06E n 015 00F SI 047 02F 079 04F O 111 06F o 016 010 DLE 048 030 0 080 050 P 112 070 p 017 011 DC1 049 031 1 081 051 Q 113...

Страница 82: ...orized agents will void this guarantee PCinterface 62 Edgewar South Australia 5154 Phone 08 8339 3865 Mobile 0419 826 262 International Phone 61 8 8339 3865 Mobile 61 419 826 262 e Road Aldgate www Le...

Отзывы: