www.LeonAudio.com.au
Select the data format for
Simple GUI Reply
or
Channel &
Function Reply
status monitoring.
Monitoring Reply Mode command
•
19.
Return Monitoring
Request Lamp Status
•
Request the Lamp Status for all channels on a specified Master.
Status data for each of the 112 Lamps is sent from the
PCinterface
to the
Show Controller.
Typical use is to update the display on a touch screen controller.
This data can be in one of two formats:-
Simple GUI Reply
and
Channel & Function Reply.
See previous page for details.
To change the reply format, see
Monitoring Reply Mode
command opposite.
Header
Master Number (0-6)
Miscellaneous Command
Request Lamp Status
Fixed value (no choices)
Request Lamp Status command
[ 1 S Q 1
Value
Command
0
1
Simple GUI Reply
Channel & Function Reply
This command configures the
PCinterface
and is remembered
when the power is off.
It does not require the
X
for e
X
ecute as it is not uploaded to the
Master Station.
It will execute as soon as the 5th byte
Value
has been received.
Monitoring Reply Mode
{
R
C
R
Configuration Header
PCinterface configuration (fixed value)
PCinterface configuration (fixed value)
Monitoring Reply Mode
Value (0-1)
Command to select
Simple GUI Reply
mode
Command to select
Channel & Function Reply
mode.
Examples
{ R C R
0
{ R C R 1
[ 1 N 92
2
Typical
Simple GUI Reply
(Master 1, Ch 1 Go flashing in this example)
[ 1 1 G 2
Typical
Channel & Function Reply
(Master 1, Ch 1 Go flashing in this example)
0