Lenze−Codestellen und CANopen−Objekte
Description of the general codes
l
59
EDSMF2181IB EN 3.0
C0200:
Software ID
Code
C0200
Name
Software manufacturer’s product code
Index: 0x5F37 (24375)
Subcode
Lenze
Values
Access
Data type
g
ro
VS
¨
RSP
þ
PS transfer
¨
CANopen:
During initialisation of the module it is determined which device is connected as a user
based on the manufacturer’s product code.
Value displayed for the 2181 communication module:
"33S2181F_10000".
C1213:
Fieldbus connection
Code
C1213
Name
Fieldbus connection
Index: 0x5B42 (23362)
Subcode
Lenze
Values
Access
Data type
0
0, 1
rw
FIX32
¨
RSP
þ
PS transfer
¨
CANopen:
In code C1213, the fieldbus connection has to be entered:
C1213 = 0
: connection of modemCAN 2181 and the inverter via the CAN bus.
C1213 = 1
: connection of modemCAN 2181 with the diagnostic interface of the
inverter9400.
)
Note!
It is not possible to operate both connections of the communication module in