Installation
•
The mounting surfaces must be plane, torsionally rigid and free from vibrations.
•
The mounting areas must be suited to absorb the forces and torques generated during
operation.
•
Ensure an unhindered ventilation.
•
For versions with a fan, keep a minimum distance of 10 % from the outside diameter of the
fan cover in intake direction.
Mounting positions
The lubricant amount and gearbox ventilation are adapted to the mounting
position. The mounting position indicated on the nameplate must be observed
to avoid damages to the gearbox.
M1
[ A ]
M2
[ D ]
M5
[ F ]
M3
[ B ]
M4
[ C ]
M6
[ E ]
Mechanical installation
Installation
Mounting positions
21