Determine change intervals for lubricants
1
.
Measure the lubricant temperature at the drain plug
2
.
Add 10 C
3
.
Determined the change interval from the diagram
Position Of the drain plug
C
D
B
A
1000
100
60
10000
50000
70
80
90
110
A
Oil sump temperature [°C]
C
Synthetic oil: CLP HC/CLP PG
B
Change interval in operating hours [h]
D
Mineral oil: CLP
Spring-applied brake
NOTICE
▶
A maintenance concept adapted to the operating conditions and the stresses to which the
brakes are subjected must be drawn up for every application.
Application brake
Holding brake with emergency
stop
Description of the operations
•
According to service life
calculation
•
At least every two years
•
Remove contamination by oil and grease with brake cleaner, if necessary
replace the brake after clarifying the cause.
•
Remove dirt and particles in the air gap between stator and armature
plate.
•
Check ventilation function and activation/deactivation
•
Check air gap (if required, re-adjust it)
•
Measure rotor thickness (if required, replace rotor)
•
Check for thermal damage of the armature plate or flange (tarnished in
dark blue)
•
Otherwise every six months
•
Standard brake: After 1 million
cycles at the latest
•
LongLife design: After 10
million cycles at the latest
•
After 4,000 operating hours at
the latest
•
Provide shorter intervals in the
case of frequent emergency
stops
Maintenance
Maintenance intervals
51