Mechanical installation
Mounting of g500 short/servo adapters with clamping connection
Maximum permissible load at the motor adapter
27
Lenze ¯ MA 12.0018 ¯ 4.1
Preparation
¯
Ensure standstill of the drive system and prevent any machine movement.
¯
The drive system must have cooled down.
¯
The motor must be deenergised.
Note!
Lenze recommends the use of smooth motor shafts without slots!
7. Check:
¯
If the drill depth in the hollow drive shaft is sufficient for the motor shaft.
–
For this purpose, compare the drill depth from the flange face with the distance
of motor shaft front side to the motor flange.
¯
Check of the motor shaft journal, the hollow shaft bore of the gearbox drive shaft,
the flange faces and the centering at the motor and gearbox for damages.
In the event of irregularities, parts have to be reworked or sorted out.