Storage
Storage up to one year:
•
Observe the climatic conditions according to the technical data
-
•
Store in a dry, low-vibration environment (V
eff
< 0.2 mm/s) without aggressive atmosphere
in the interior
•
Protect from dust, shocks and sunlight
•
Avoid temperature changes with condensate formation.
•
Store gearboxes with a ventilation unit with the ventilation element on top.
•
Do not activate ventilation unit, in order to prevent air exchange with the ambient air.
•
Treat damaged corrosion protection on shafts and bare surfaces subsequently
Storage for more than one year, up to two years:
•
Apply a long−term corrosion preventive (e.g. Anticorit BW 366 from the Fuchs company) to
the shafts and uncoated surfaces before storing the motor away.
•
Do not activate ventilation element
•
Install gearbox in mounting position M1 (A)
•
Fill gearbox with the lubricant type filled in (see nameplate) up to the filling/venting bore
for mounting position M1 (A)
-
-