Protection of persons and device protection
Degree of protection
EN
EN IEC 60529,EN IEC
60034-5
IP55
Information applies to the mounted and ready-
for-use state
NEMA
NEMA 250
Type 12
Type 4 indoor only
Depending on the configuration
Insulation resistance
Overvoltage category EN IEC 61800-5-1
II
>2000 m amsl
III
0 … 2000 m amsl
Isolation of control circuits
-
EN IEC 61800-5-1
Safe mains isolation
Double/reinforced insulation
Connect overvoltage device upstream
Site altitude above 200 m amsl: Additional
external separation measures are required to
maintain safe separation.
Protective measures
Earth fault strength
-
To a limited extent, error acknowledgement required
Motor stalling
protection
Yes
Short-circuit strength
To a limited extent, error acknowledgement required
Overvoltage
resistance
Yes
Motor
overtemperature
I²xt monitoring
Leakage current
AC
EN IEC 61800-5-1
> 3.5 mA
Please observe regulations and safety
instructions!
Equipotential
bonding
-
Additional M5 thread with terminal on the terminal box for connection of a 6mm² PE cable
Total fault current
Earth-leakage circuit
breaker
-
In TN systems
Cyclic mains switching
3 times per minute,
max. 20 times per
hour
-
After switching the mains 3 times in one minute, there must be a switching pause of 9 minutes.
Starting current
-
-
5.6 A mains power-on current
EMC data
Operation on public supply systems
-
-
The machine or system manufacturer is responsible for compliance with the requirements for the
machine/system!
< 1 kW
EN IEC 61000-3-2
With mains choke
> 1 kW, mains
current ≤ 16 A
No additional measures
Mains current > 16
A ... ≤ 75 A
EN IEC 61000-3-12
With mains choke or mains filter
When designed for rated power.
Noise emission
Fulfills requirements
according to
EN IEC 60034-1
A final overall assessment of the drive system is indispensable
Category C2
EN IEC 61800-3
see rated data
Noise immunity
-
EN IEC 61800-3
Requirements for industrial environment are met
Technical data
Standards and operating conditions
Protection of persons and device protection