Connection according to cULus
The following data is valid for a three-phase mains connection with 480 V.
Mains connection with QUICKON connector
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Connection type
QUICKON connector
Cable cross-section
Typ.
AWG
16
14
Min.
AWG
16
16
Max.
AWG
14
14
Mains connection M15 connector
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Connection type
M15 connector
Cable cross-section
Typ.
AWG
16
14
Min.
AWG
16
16
Max.
AWG
14
14
Mains connection cable L1, L2, L3, PE
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Connection
X3
Connection type
Cable
Cable type
rigid/flexible
Cable cross-section
Typ.
AWG
18
16
Min.
AWG
18
18
Max.
AWG
16
16
Stripping length
mm
10
10
Information on electrical installation
Connection according to cULus