![Lenze g500-H Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/lenze/g500-h/g500-h_manual_1882419035.webp)
Single drive connection according to EN IEC 60204−1
L1
3/N/PE AC 400/480 V
L1
L2
L3
N
PE
F1 … F3
L2 L3
SELV/PELV
DC 24 V
(+19.2 … +28.8 V)
5.6k
5.6k
R
b
M
3~
Rb1
Rb2
V
U
W
+
+
X3
X4
+
1
2
3
BD1
BD2
X2
1
2
3
4
X1
1
2
3
4
X5
max. 50 mA
X6
GND
-I
DI1
DI2
n. c.
5.6k
GND
-O
DO1
DI3
24V
DC
AC
Q
400
1
2
3
4
1
2
3
4
Rb1
Rb2
X4
R
b
Rb1 Rb2
390
①
L1
F1 … F3
L2 L3
+
+
X3
Q
2
3
A
B
1
+
①
GND is bridged if the "DI/DO−GND bridged" version is specified on the nameplate.
Fuse data (F1 ... F3)
Motor
MSEMA
☐☐
063-42
MSEMA
☐☐
080-32
Cable installation in accordance
with
EN IEC 60204−1
Laying system
B2
Fuse
Characteristic
gG/gL
Typ. Rated current
A
6
10
Max. rated current
A
16
16
Semiconductor fuse
Characteristic
gRL
Typ. Rated current
A
6
10
Max. rated current
A
16
16
Circuit breaker
Characteristic
C
Typ. Rated current
6
10
Max. rated current
A
16
16
•
Use of copper cables insulated with PVC
•
Conductor temperature < 70 °C, ambient temperature < 40 °C
•
No bundling of cables or wires, thee wires under load
Information on electrical installation
Connection according to EN