Configuration
7-10
820XBA1097
Code
IMPORTANT
Possible settings
Name
Code
IMPORTANT
Info
Selection
Lenze
Name
C144
§
Chopper-frequency
reduction
§
821X/822X/824
X
-1-
-0-
No chopper-frequency reduction
-1-
Automatic chopper-frequency lowering
when
J
max
- 10
C
C161* Current fault
Only display
C162* Last fault
Only display
C163* Last but one
fault
Only display
C164* Last but two
fault
Only display
C170
§
TRIP-reset
selection
-0-
TRIP-reset by pressing the STP key or
LOW signal at ctrl. enable
-1-
Auto-TRIP-Reset
C171 Delay for
Auto-TRIP-Reset
0
0
{1s}
60
C178* Operating time
Only display
C179* Mains switch-on
time
Only display
C377 Gain Zk-voltage
detection
822X/824X
Should only
be changed
by the Lenze
Service!
C500* Display factor
application
datum
numerator
821X/822X/824
X
2000
1
{1}
25000
C501* Display factor
for process
variable
denominator
821X/822X/824
X
10
1
{1}
25000