Lenze 13466184 EDBSL03 v20
EN
, DE, FR, IT, ES
19
Commissioning
Code
Possible Settings
IMPORTANT
No.
Name
Lenze
Selection
d25
PI setpoint accel/
decel
5.0 0.0 {s} 999 Sets rate of change for PI setpoint
d38
PI mode
0
0 PI disabled
1 PI enabled: normal-acting
When feedback (terminal 8) exceeds
setpoint, speed decreases
2 PI enabled: reverse-acting
When feedback (terminal 8) exceeds
setpoint, speed increases
d46
Feedback minimum
alarm
0.0 0.0 999
See C08 and c17, selections 9 and 10
d47
Feedback maximum
alarm
0.0 0.0 999
n20
LECOM power up
state
0
0 Quick stop
1 Inhibit
n22
Serial time-out
action
0
0 Not active
Selects controller reaction to serial
timeout
1 Inhibit
2 Quick stop
3 Trip fault
FC3
n23
Serial fault time
50
50
{ms}
65535 Sets the serial timeout length