Electrical installation
Safety engineering
l
72
EDKLCFH3024−EER DE/EN 2.0
X60 − Sichere Eingänge, sichere Ausgänge
Pin
Signal
Beschreibung
Daten
Connector: female, 26−pin, M27, N−coded
1
O1A
Safe monitor SD−Out1, channel A
2
O1B
Safe monitor SD−Out1, channel B
3
GO
Reference potential for SD−Out1
4
n. c.
Not assigned
5
n. c.
Not assigned
6
n. c.
Not assigned
7
CLB
Clock output for passive sensors,
Channel B (Clock B)
8
CLA
Clock output for passive sensors,
Channel A (Clock A)
9
GCL
Reference potential for clock output
10
I1A
Sensor input SD−In1, channel A
11
I1B
Sensor input SD−In1, channel B
12
GI1
Reference potential for SD−In1
13
I2A
Sensor input SD−In2, channel A
14
I2B
Sensor input SD−In2, channel B
15
GI2
Reference potential for SD−In2
16
I3A
Sensor input SD−In3, channel A
17
I3B
Sensor input SD−In3, channel B
18
GI3
Reference potential for SD−In3
19
I4A
Sensor input SD−In4, channel A
20
I4B
Sensor input SD−In4, channel B
21
GI4
Reference potential for SD−In4
22
AIE
Error acknowledgement input
("Acknowledge In Error")
23
AIS
Restart acknowledgement input
("Acknowledge In Stop")
24
n. c.
Not assigned
25
n. c.
Not assigned
26
n. c.
Not assigned