Technical data
General data and operating conditions
l
56
EDKLCFH3024−EER DE/EN 2.0
Operating conditions
Ambient conditions
Climatic
Storage
IEC/EN 60721−3−1
1K3 (−20 ... +60 °C)
< 6 months
1K3 (−20 ... +40 °C)
> 6 months
> 2 years: anodise DC bus
capacitors
Transport
IEC/EN 60721−3−2
2K3 (−20 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (0 ... +55 °C)
> +40 °C: reduce the rated output current by 2.5 %/°C.
Site altitude
< 4000 m amsl
Reduce the rated output current by 5%/1000 m above
1000 m amsl.
Pollution
EN 61800−5−1
Degree of pollution 2
Mechanical
Vibration resistance
Germanischer Lloyd
General conditions: acceleration resistant up to 0.7 g
Electrical
Mains connection
Mains system
TT, TN
(earthed neutral)
Unrestricted operation permitted.
IT
Operation not permitted.
Motor connection
Length of the motor
cable
< 20 m (Lenze system cable, shielded)
Cable length for
speed feedback
< 20 m (Lenze system cable, shielded)
Mounting conditions
Mounting location
Wall, mounting plate
Mounting positions
Standard mounting
Vertically suspended, front display
Desk−type mounting
Inclined by maximally 30 ° to the back
Free space
^