25 RG-MHMOD
Drive Control & Communication
NOTE 4 - Acceleration Limits
Acceleration Limits
HP
Adjustment Range
0.25 - 20
1 - 36000 (0.1 - 3600 sec)
25 - 60
3 - 36000 (0.3 - 3600 sec)
75 - 250
6 - 36000 (0.6 - 3600 sec)
NOTE 5 - Deceleration Limits
Deceleration Limits
HP
Adjustment Range
240/200 VAC
480/400 VAC
590/480 VAC
without dB
with dB
0.25 - 7.5
1 - 7.5
3 - 36000 (0.3 - 3600 sec)
1 - 36000 (0.1 - 3600 sec)
10 - 15
10 - 20
1 - 7.5
5 - 36000 (0.5 - 3600 sec)
1 - 36000 (0.1 - 3600 sec)
20 - 30
25 - 60
10 - 20
10 - 36000 (1.0 - 3600 sec)
2 - 36000 (0.2 - 3600 sec)
25 - 60
20 - 36000 (2.0 - 3600 sec)
2 - 36000 (0.2 - 3600 sec)
NOTE 6 - MAX DC BRAKE VOLTAGE (Register 63)
Maximum DC Brake Voltage
Model
MH100
MH200
MH400
MH500
Voltage
240/120 Vac
240/200 Vac
480/400 Vac
590/480 Vac
MAX Brake Voltage
24 V
24 V
48 V
59 V
NOTE 7 - CURRENT (Register 67)
If LINE VOLTS, Register 51, is set to LOW (or set to Auto and the input voltage is low), the range for
CURRENT is 25 - 150%.
NOTE 8 - FX BOOST (Register 70)
FX BOOST Factory Default Setting
HP
Factory Default
HP
Factory Default
0.25 - 1
5.30%
15
2.20%
1.5 - 2
4.40%
20
2.00%
3
3.60%
25
1.80%
5
3.00%
30
1.60%
7.5
2.70%
40
1.20%
10
2.40%
50 - 60
0.80%